Literature DB >> 3404293

The accuracy of alkaline phosphatase isoenzyme determination.

G C Lamb1, G Roush.   

Abstract

Alkaline phosphatase isoenzyme determination (APID) is in common use despite evidence suggesting that the results correlate poorly with actual sites of disease. To assess the predictive value of this test in clinical practice, 99 APIDs performed on 94 patients were identified and the patients' charts were reviewed. Results of APID were compared with actual patient diagnoses as determined by other means. The liver isoenzyme fraction was not very accurate in predicting the presence of liver disease (positive predictive value 68%). In contrast, the bone isoenzyme fraction was insensitive (56%) but a positive test predicted bone disease well (positive predictive value 93%). The association of elevated transaminases with elevated alkaline phosphatase on a chemistry profile was as useful as APID in identifying liver disease, suggesting that APID should not be done in this setting. Using this information, APID can be helpful in the assessment of an ill patient with an elevated alkaline phosphatase.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3404293     DOI: 10.1007/bf02595789

Source DB:  PubMed          Journal:  J Gen Intern Med        ISSN: 0884-8734            Impact factor:   5.128


  6 in total

1.  Clinical usefulness of alkaline phosphatase isoenzyme determinations.

Authors:  L Gorman; B E Statland
Journal:  Clin Biochem       Date:  1977-10       Impact factor: 3.281

Review 2.  Perspectives on alkaline phosphatase isoenzymes.

Authors:  W H Fishman
Journal:  Am J Med       Date:  1974-05       Impact factor: 4.965

3.  The clinical usefulness of alkaline phosphatase isoenzyme determinations.

Authors:  J Winkelman; S Nadler; J Demetriou; V J Pileggi
Journal:  Am J Clin Pathol       Date:  1972-05       Impact factor: 2.493

4.  Quantitative alkaline phosphatase isoenzyme determination by electrophoresis on cellulose acetate membranes.

Authors:  W H Siede; U B Seiffert
Journal:  Clin Chem       Date:  1977-01       Impact factor: 8.327

Review 5.  The measurement of serum alkaline phosphatase in clinical medicine.

Authors:  S Posen; E Doherty
Journal:  Adv Clin Chem       Date:  1981       Impact factor: 5.394

6.  Separation of alkaline phosphatase isoenzymes and evaluation of the clinical usefulness of this determination.

Authors:  L M Ewen
Journal:  Am J Clin Pathol       Date:  1974-02       Impact factor: 2.493

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.