| Literature DB >> 34040291 |
Raheleh Hedayati1, Sepideh Hekmat2, Fereydoun Rastgou3, Nahid Yaghoobi3, Hasan Firoozabadi3, Ahmad Bitarafan-Rajabi3, Hadi Malek3, Somaie Arabshameli3.
Abstract
PURPOSE OF THE STUDY: The aim of our study was to compare the technetium-99m (Tc-99m)-ethylenedicysteine (EC) renography calculation of differential renal function (DRF) with this measurement using Tc-99m-dimercaptosuccinic acid (DMSA) scintigraphy.Entities:
Keywords: Differential renal function; technetium-99m-dimercaptosuccinic acid; technetium-99m-ethylenedicysteine
Year: 2021 PMID: 34040291 PMCID: PMC8130686 DOI: 10.4103/ijnm.IJNM_94_20
Source DB: PubMed Journal: Indian J Nucl Med ISSN: 0974-0244
Frequency table of ethylenedicysteine scintigraphy and dimercaptosuccinic acid scintigraphy showing number of patients, mean, standard deviation, and range of measurements
| Mean±SD (%) | Range (%) | ||
|---|---|---|---|
| Right kidney function (Tc-99m-EC) | 42 | 50±21.2 | 96.4 |
| Right kidney function (Tc-99m) | 42 | 50±18.2 | 96.4 |
| Right kidney function (Tc-99m-EC) DMSA - male | 32 | 50±18.7 | 96.4 |
| Right kidney function (Tc-99m-DMSA) - male | 32 | 50±16.9 | 96.4 |
| Right kidney function (Tc-99m-EC) -female | 10 | 50±29.2 | 85 |
| Right kidney function (Tc-99m-EC) - female | 10 | 50±22.9 | 67.7 |
EC: Ethylenedicysteine, DMSA: Dimercaptosuccinic acid, SD: Standard deviation
Figure 1Plot of measured renal function of the right kidney of each patient with ethylenedicysteine scintigraphy versus dimercaptosuccinic acid scintigraphy in children (n = 42)
Figure 2Comparisons of differential renal function calculated by technetium-99m-ethylenedicysteine and technetium-99mdimercaptosuccinic acid, using the Bland–Altman plot (n = 42)