AAPM Task Group 198 Report: An Implementation Guide for TG 142 Quality Assurance of Medical Accelerators.

Joseph Hanley1, Sean Dresser2, William Simon3, Ryan Flynn4, Eric E Klein5, Daniel Letourneau6, Chihray Liu7, Fang-Fang Yin8, Bijan Arjomandy9, Lijun Ma10, Francisco Aguirre11, Jimmy Jones12, John Bayouth13.   

Abstract

The charges on this task group (TG) were as follows: (1) provide specific procedural guidelines for performing the tests recommended in TG 142; (2) provide estimate of the range of time, appropriate personnel, and qualifications necessary to complete the tests in TG 142; (3) provide sample daily, weekly, monthly, or annual quality assurance (QA) forms. Many of the guidelines in this report are drawn from the literature and are included in the references. When literature was not available, specific test methods reflect the experiences of the TG members (for example, a test method for door interlock is self-evident with no literature necessary). In other cases, the technology is so new that no literature for test methods was available. Given broad clinical adaptation of volumetric modulated arc therapy (VMAT), which is not a specific topic of TG 142, several tests and criteria specific to VMAT were added. This article is protected by copyright. All rights reserved.

Keywords:  QA; accelerator; quality assurance; radiotherapy

Year:  2021        PMID: 34036590     DOI: 10.1002/mp.14992

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

1.  Variation in Elekta iView electronic portal imager pixel scale factor with gantry angle, and impact on multi-leaf collimator quality assurance.

Authors:  Simon K Goodall; Craig Norvill
Journal:  J Appl Clin Med Phys       Date:  2022-06-06       Impact factor: 2.243

2.  Comparison of MLC positioning deviations using log files and establishment of specific assessment parameters for different accelerators with IMRT and VMAT.

Authors:  Xiutong Lin; Tao Sun; Xiao Liu; Guifang Zhang; Yong Yin
Journal:  Radiat Oncol       Date:  2022-07-16       Impact factor: 4.309

3.  Impact of a Centralized Database System on Radiation Therapy Quality Assurance Management at a Large Health Care Network: 5 Years' Experience.

Authors:  Grace Tang; Thomas LoSasso; Maria Chan; Margie Hunt
Journal:  Pract Radiat Oncol       Date:  2022-04-14

4.  Detection of rotational errors in single-isocenter multiple-target radiosurgery: Is a routine off-axis Winston-Lutz test necessary?

Authors:  Lauren M M Pudsey; Giordano Biasi; Anna Ralston; Anatoly Rosenfeld; Joel Poder
Journal:  J Appl Clin Med Phys       Date:  2022-06-17       Impact factor: 2.243