Design of an anthropomorphic PET phantom with elastic lungs and respiration modeling.

David G Black1, Yas Oloumi Yazdi1, Jeremy Wong1, Roberto Fedrigo1,2, Carlos Uribe3,4, Dan J Kadrmas5, Arman Rahmim1,2,4, Ivan S Klyuzhin2,4.   

Abstract

PURPOSE: Respiratory motion during positron emission tomography (PET) scans can be a major detriment to image quality in oncological imaging. The impact of motion on lesion quantification and detectability can be assessed using phantoms with realistic anatomy representation and motion modeling. In this work, we develop an anthropomorphic phantom for PET imaging that combines anatomic fidelity and a realistic breathing mechanism with deformable lungs.
METHODS: We start from a previously developed anatomically accurate but static phantom of a human torso, and add elastic lungs with a highly controllable actuation mechanism which replicates the physics of breathing. The space outside the lungs is filled with a radioactive water solution. To maintain anatomical accuracy and realistic gamma ray attenuation in the torso, all motion mechanisms and actuators are positioned outside of the phantom compartment. The actuation mechanism can produce custom respiratory waveforms with breathing rates up to 25 breaths per minute and tidal volumes up to 1200 mL.
RESULTS: Several tests were performed to validate the performance of the phantom assembly, in which the phantom was filled with water and given respiratory waveforms to execute. All parts demonstrated expected performance. Force requirements were not exceeded and no leaks were detected, although continued use of the phantom is required to evaluate wear. The motion of the lungs was determined to be within a reasonable realistic range.
CONCLUSIONS: The full mechanical design is described in this paper, as well as a software application with graphical user interface which was developed to plan and visualize respiratory patterns. Both are available online as open source files. The developed phantom will facilitate future work in evaluating the impact of respiratory motion on lesion quantification and detectability in clinical practice.
© 2021 American Association of Physicists in Medicine.

Entities:  

Keywords:  anthropomorphic phantom; motion correction; motion management; pet; phantoms - physical; quantitative imaging/analysis

Year:  2021        PMID: 34031896     DOI: 10.1002/mp.14998

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  2 in total

1.  Technical note: Low-cost MR-compatible pneumatic respiratory organ motion simulator for the development of MR-guided thermal therapy.

Authors:  Kisoo Kim; Peter Jones; Chris Diederich; Eugene Ozhinsky
Journal:  Med Phys       Date:  2022-06-07       Impact factor: 4.506

Review 2.  Absolute Quantification in Diagnostic SPECT/CT: The Phantom Premise.

Authors:  Stijn De Schepper; Gopinath Gnanasegaran; John C Dickson; Tim Van den Wyngaert
Journal:  Diagnostics (Basel)       Date:  2021-12-11
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.