Literature DB >> 34030142

Quantitative analysis of bone microvasculature in a mouse model using the monogenic signal phase asymmetry and marker-controlled watershed.

Hao Xu1, Max Langer1, Françoise Peyrin1,2.   

Abstract

Thethree-dimensional (3D) imaging and quantitative analysis of bone microvasculature are important to describe angiogenesis involvement in bone metastatic processes. Here, we propose an algorithm based on marker-controlled watershed for the 3D segmentation of vessels and bone in mouse bone imaged with a contrast agent using synchrotron radiation micro-computed tomography (SR-μCT). Markers were generated using hysteresis thresholding and morphological filters, and the control surface was constructed using the monogenic signal phase asymmetry. The accuracy and robustness of the proposed method were evaluated on a series of synthetic volumes generated to mimic the vessel, bone and background structures. Different contrast between different structures, as well as different noise levels were considered. A series of multi-class synthetic volumes were segmented using the proposed method, and the overall segmentation quality was evaluated using the Matthews correlation coefficient (MCC) by comparing to the ground truth. Additionally, we evaluated the segmentation of thin structures under various levels of Gaussian noise. The simulation study indicated that the algorithm was performant in multi-class segmentation with different contrast, noise, and thickness. The algorithm was applied to images of bone from a mouse model of breast cancer bone metastasis acquired using SR-μCT. The segmentation quality was evaluated using the Dice coefficient and the MCC by comparing to manual segmentation. The proposed method performed better than hysteresis thresholding and marker-controlled watershed using the magnitude of the gradient as control surface. Several quantitative parameters on bone and vessels were extracted, including bone volume fraction (BV/TV), vessel volume fraction (VV/TV) and the mean vessel thickness (VTh). The bone volume fraction (BV/TV) was significantly lower in the metastatic group compared to the healthy group. This demonstrated the effectiveness of the algorithm for the study of bone and vessel microstructures in mouse model.
© 2021 Institute of Physics and Engineering in Medicine.

Entities:  

Keywords:  bone; micro-computed tomography; monogenic signal; segmentation; vessel; watershed

Mesh:

Year:  2021        PMID: 34030142     DOI: 10.1088/1361-6560/ac047d

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  1 in total

1.  Impact of Anti-Angiogenic Treatment on Bone Vascularization in a Murine Model of Breast Cancer Bone Metastasis Using Synchrotron Radiation Micro-CT.

Authors:  Hao Xu; Marie-Hélène Lafage-Proust; Lamia Bouazza; Sandra Geraci; Philippe Clezardin; Bernard Roche; Françoise Peyrin; Max Langer
Journal:  Cancers (Basel)       Date:  2022-07-15       Impact factor: 6.575

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.