Literature DB >> 34027968

Static cold storage compared with normothermic machine perfusion of the liver and effect on ischaemic-type biliary lesions after transplantation: a propensity score-matched study.

M Fodor1, B Cardini1, W Peter1, A Weissenbacher1, R Oberhuber1, T Hautz1, G Otarashvili1, C Margreiter1, M Maglione1, T Resch1, F Krendl1, A T Meszaros1, C Bogensperger1, S Gasteiger1, F Messner1, B Henninger2, H Zoller3, H Tilg3, D Öfner1, S Schneeberger1.   

Abstract

BACKGROUND: Given the susceptibility of organs to ischaemic injury, alternative preservation methods to static cold storage (SCS), such as normothermic machine perfusion (NMP) are emerging. The aim of this study was to perform a comparison between NMP and SCS in liver transplantation with particular attention to bile duct lesions.
METHODS: The outcomes of 59 consecutive NMP-preserved donor livers were compared in a 1 : 1 propensity score-matched fashion to SCS control livers. Postoperative complications, patient survival, graft survival and bile duct lesions were analysed.
RESULTS: While patients were matched for cold ischaemia time, the total preservation time was significantly longer in the NMP group (21 h versus 7 h, P < 0.001). Patient and graft survival rates at 1 year were 81 versus 82 per cent (P = 0.347) and 81 versus 79 per cent (P = 0.784) in the NMP and SCS groups, respectively. The postoperative complication rate was comparable (P = 0.086); 37 per cent NMP versus 34 per cent SCS patients had a Clavien-Dindo grade IIIb or above complication. There was no difference in early (30 days or less) (NMP 22 versus SCS 19 per cent, P = 0.647) and late (more than 30 days) (NMP 27 versus SCS 36 per cent, P = 0.321) biliary complications. However, NMP-preserved livers developed significantly fewer ischaemic-type bile duct lesions (NMP 3 versus SCS 14 per cent, P = 0.047).
CONCLUSION: The use of NMP allowed for a significantly prolonged organ preservation with a lower rate of observed ischaemic-type bile duct lesions.
© The Author(s) 2021. Published by Oxford University Press on behalf of BJS Society Ltd. All rights reserved. For permissions, please email: journals.permissions@oup.com.

Entities:  

Mesh:

Year:  2021        PMID: 34027968     DOI: 10.1093/bjs/znab118

Source DB:  PubMed          Journal:  Br J Surg        ISSN: 0007-1323            Impact factor:   6.939


  11 in total

1.  Plead for a paradigm shift in machine perfusion indications in liver transplantation.

Authors:  Damiano Patrono; Renato Romagnoli
Journal:  Updates Surg       Date:  2022-06-25

2.  Correlation of Different Serum Biomarkers with Prediction of Early Pancreatic Graft Dysfunction Following Simultaneous Pancreas and Kidney Transplantation.

Authors:  Nora Jahn; Maria Theresa Voelker; Sven Laudi; Sebastian Stehr; Stefan Schneeberger; Gerald Brandacher; Elisabeth Sucher; Sebastian Rademacher; Daniel Seehofer; Robert Sucher; Hans Michael Hau
Journal:  J Clin Med       Date:  2022-05-03       Impact factor: 4.964

3.  The Role of NMP22 and CSTB Levels in Predicting Postoperative Recurrence of Bladder Cancer.

Authors:  Changkun Huang; Xiaolin Ai; Liping Hu; Da Ren
Journal:  J Immunol Res       Date:  2022-05-19       Impact factor: 4.493

Review 4.  Hospital-Based Health Technology Assessment of Machine Perfusion Systems for Human Liver Transplantation.

Authors:  Paolo De Simone; Davide Ghinolfi
Journal:  Transpl Int       Date:  2022-05-27       Impact factor: 3.842

Review 5.  Normothermic Machine Perfusion-Improving the Supply of Transplantable Livers for High-Risk Recipients.

Authors:  Angus Hann; Anisa Nutu; George Clarke; Ishaan Patel; Dimitri Sneiders; Ye H Oo; Hermien Hartog; M Thamara P R Perera
Journal:  Transpl Int       Date:  2022-05-31       Impact factor: 3.842

6.  Hyperspectral Imaging as a Tool for Viability Assessment During Normothermic Machine Perfusion of Human Livers: A Proof of Concept Pilot Study.

Authors:  Margot Fodor; Lukas Lanser; Julia Hofmann; Giorgi Otarashvili; Marlene Pühringer; Benno Cardini; Rupert Oberhuber; Thomas Resch; Annemarie Weissenbacher; Manuel Maglione; Christian Margreiter; Philipp Zelger; Johannes D Pallua; Dietmar Öfner; Robert Sucher; Theresa Hautz; Stefan Schneeberger
Journal:  Transpl Int       Date:  2022-05-16       Impact factor: 3.842

7.  Artificial Intelligence Algorithm-Based CTA Imaging for Diagnosing Ischemic Type Biliary Lesions after Orthotopic Liver Transplantation.

Authors:  Zhenxing Yu; Guixue Ou; Ruihua Wang; Qinghua Zhang
Journal:  Comput Math Methods Med       Date:  2022-01-04       Impact factor: 2.238

8.  Outcome of liver transplantation with grafts from brain-dead donors treated with dual hypothermic oxygenated machine perfusion, with particular reference to elderly donors.

Authors:  Damiano Patrono; Davide Cussa; Veronica Sciannameo; Elena Montanari; Rebecca Panconesi; Paola Berchialla; Mirella Lepore; Alessandro Gambella; Giorgia Rizza; Giorgia Catalano; Stefano Mirabella; Francesco Tandoi; Francesco Lupo; Roberto Balagna; Mauro Salizzoni; Renato Romagnoli
Journal:  Am J Transplant       Date:  2022-02-22       Impact factor: 9.369

9.  Analysis of Volatile Anesthetic-Induced Organ Protection in Simultaneous Pancreas-Kidney Transplantation.

Authors:  Nora Jahn; Maria Theresa Völker; Sven Laudi; Sebastian Stehr; Stefan Schneeberger; Gerald Brandacher; Elisabeth Sucher; Sebastian Rademacher; Daniel Seehofer; Hans Michael Hau; Robert Sucher
Journal:  J Clin Med       Date:  2022-06-13       Impact factor: 4.964

Review 10.  Machine Perfusion for Extended Criteria Donor Livers: What Challenges Remain?

Authors:  Jeannette Widmer; Janina Eden; Mauricio Flores Carvalho; Philipp Dutkowski; Andrea Schlegel
Journal:  J Clin Med       Date:  2022-09-03       Impact factor: 4.964

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.