Literature DB >> 3402505

Observation of portal circulation through superior mesenteric vein by enteric coated capsule of thallium-201.

N Tonami1, K Nakajima, N Watanabe, M Seto, K Yokoyama, N Shuke, T Michigishi, T Takayama, T Aburano, K Hisada.   

Abstract

A new method of oral administration of an enteric coated capsule of 201Tl (201Tl-capsule) was developed to evaluate the portal circulation through the superior mesenteric vein (SMV). The 201Tl-capsule was not collapsed in the artificial gastric juice, whereas it melted soon after soaking in the artificial intestinal juice. In a clinical trial of 42 cases, 201Tl was satisfactory released in the duodenum in 36 cases where clear liver images were observed except in 1 patient. Heart to liver ratio (H/L) at 60 or 90 min after duodenal release of 201Tl was 0.32 +/- 0.07 (mean +/- 1 s.d.) in normal controls, 0.34 +/- 0.12 in chronic hepatitis, 0.31 +/- 0.12 in acute hepatitis, 0.45 +/- 0.13 in liver cirrhosis and 0.48 +/- 0.32 in cirrhosis with hepatocellular carcinoma. In 11 patients who had both oral and rectal studies with 201Tl, 7 showed a high H/L ratio of more than 0.8 in the rectal study but only 1 showed a similarly high ratio of 1.07 in the oral study. In the group of varied liver disorders we have studied so far, it was found that most of the SMV blood flowed into the liver and the degree of portal systemic shunting (PSS) from the SMV was much smaller compared to that from the inferior mesenteric vein. The present study with oral administration of the 201Tl-capsule was of value in understanding portal circulation through the SMV, however, this technique seemed of limited usefulness for evaluating overall pathologic PSS.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3402505     DOI: 10.1007/bf00293539

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  7 in total

1.  Influence of portal-systemic collateral patterns and distribution of varices on results of surgical treatment of bleeding esophageal varices.

Authors:  R C BRITTON
Journal:  Surgery       Date:  1963-05       Impact factor: 3.982

2.  201Tl per-rectal scintigraphy in primary hepatocellular carcinoma.

Authors:  N Tonami; K Nakajima; K Hisada; O Matsui; M Kadoya; T Takashima
Journal:  Nucl Med Commun       Date:  1985-06       Impact factor: 1.690

3.  A noninvasive method for evaluating portal circulation by administration of Ti-201 per rectum.

Authors:  N Tonami; K Nakajima; K Hisada; N Tanaka; K Kobayashi
Journal:  J Nucl Med       Date:  1982-11       Impact factor: 10.057

4.  Dynamic studies on portal haemodynamics by scintiphotosplenoportography: flow patterns of portal circulation.

Authors:  T Kashiwagi; K Kimura; T Suematsu; M Shichiri; T Kamada; H Abe
Journal:  Gut       Date:  1980-01       Impact factor: 23.059

5.  Thallium-201 for medical use. II: Biologic behavior.

Authors:  P R Bradley-Moore; E Lebowitz; M W Greene; H L Atkins; A N Ansari
Journal:  J Nucl Med       Date:  1975-02       Impact factor: 10.057

6.  The clinical value of 201Tl per rectum scintigraphy in the work-up of patients with alcoholic liver disease.

Authors:  D Urbain; P Reding; B Georges; O Thys; H R Ham
Journal:  Eur J Nucl Med       Date:  1986

7.  Evaluation of portal circulation in rats by rectal administration of 201Tl followed by intrasplenic injection of 51Cr-labeled microspheres.

Authors:  S Matsumoto; K Fukuda; S Morita; N Umezaki; M Arakawa; Y Moriguchi; H Ohtake
Journal:  Eur J Nucl Med       Date:  1985
  7 in total
  3 in total

1.  Assessment of portosystemic shunting from superior mesenteric vein by duodenal administration of iodoamphetamine I123.

Authors:  T Kashiwagi; H Fukui; T Kozuka; M Goto; Y Takei; A Kasahara; S Kawano; H Fusamoto; T Kamada; M Azuma
Journal:  Eur J Nucl Med       Date:  1992

2.  Contribution of scintigraphy to verify the reliability of different preparation processes for enteric coated capsules.

Authors:  D Catteau; C Barthélémy; M Deveaux; H Robert; F Trublin; X Marchandise; H Van Drunen
Journal:  Eur J Drug Metab Pharmacokinet       Date:  1994 Apr-Jun       Impact factor: 2.441

3.  Evaluation of portal circulation through the superior mesenteric vein with an enteric capsule of [123I]iodoamphetamine.

Authors:  S Shiomi; T Kuroki; Y Miyazawa; T Ueda; T Takeda; S Nishiguchi; S Nakajima; K Kobayashi; H Ochi
Journal:  J Gastroenterol       Date:  1995-02       Impact factor: 7.527

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.