Ruben Dukan1, Malo Le Hanneur2, Stéphanie Pannier3, Franck Fitoussi2.
Abstract
The incidence of untreated Monteggia fracture-dislocations is not insignificant. But there is no consensus as to the surgical indication and best surgical technique to use. Single-stage reduction of the radial head through an elbow arthrotomy and ulnar osteotomy is a complex surgical procedure that requires stabilization of the ulnar segments during every step of the intervention. Here, we describe the possibility of using an external fixator intraoperatively to facilitate the various steps of the procedure: (1) gradual distraction and angulation of the osteotomy site to allow thorough excision of any interposed capsular tissue, (2) stable hold on the ulnar fragments independent of the surgical assistant, which allows the stability of the radial head reduction to be tested in pronation and supination and (3) facilitation of plate fixation at the ulnar osteotomy site. LEVEL OF EVIDENCE: IV; case series.Entities:
Keywords: Dislocation; External fixator; Monteggia; Radial head
Mesh:
Year: 2021 PMID: 34022463 DOI: 10.1016/j.otsr.2021.102963
Source DB: PubMed Journal: Orthop Traumatol Surg Res ISSN: 1877-0568 Impact factor: 2.256