The application value of oXiris-endotoxin adsorption in sepsis.

Yanping Zhai1, Jiayu Pan1, Chunyun Zhang1.   

Abstract

OBJECTIVES: This study explored and analyzed the application value of oXiris- endotoxin adsorption technology in patients with sepsis.
METHODS: 23 sepsis patients hospitalized from January 2018 to September 2019 in our ICU center and received oxiris-endotoxin adsorption were enrolled as the observation group, and another 30 sepsis patients hospitalized during the same period were selected as the control group who treated with routine continuous renal replacement therapy (CRRT). The heart rate, respiratory rate, norepinephrine (NE) dosage, lactic acid, procalcitonin (PCT), urine volume, and sofa scores that evaluate organ failure after systemic infection, as well as ICU stay, organ support duration, and incidence of cardiovascular events were compared between the two groups before and after treatment.
RESULTS: The heart rate, respiratory rate and NE dosage of the two groups post-treatment were dramatically lower than those pre-treatment (P<0.05), and these indexes in observation group after treatment were critically lower than those in control group (P<0.05). The lactic acid, PCT, urine volume and sofa scores of the two groups were dramatically lower than those before treatment (P<0.05), and the indexes in observation group after treatment were notably lower than those in control group (P<0.05). The degree of serum IL-6, IL-10 and endotoxin in two groups after operation decreased remarkably than that before treatment (P<0.05), and the observation group had obviously lower indicator degree than the control group (P<0.05). The ICU stay, organ support duration, and incidence of cardiovascular events in the observation group were notably lower than those in the control group (P<0.05).
CONCLUSION: compared with the traditional CRRT technology, the oXiris membrane based CRRT technology can effectively improve the hemodynamic indicators of patients with sepsis, reduce the level of inflammation, and improve the metabolic function of body, thereby improving the patients' organ function. It has good clinical application value in patients with sepsis. AJTR
Copyright © 2021.

Entities:  

Keywords:  application value; endotoxin adsorption technology; oXiris; sepsis

Year:  2021        PMID: 34017574      PMCID: PMC8129347     

Source DB:  PubMed          Journal:  Am J Transl Res        ISSN: 1943-8141            Impact factor:   4.060


  2 in total

1.  Soluble ST2 Is a Sensitive and Specific Biomarker for Fulminant Myocarditis.

Authors:  Jin Wang; Mengying He; Huihui Li; Yanghui Chen; Xiang Nie; Yuanyuan Cai; Rong Xie; Lijuan Li; Peng Chen; Yang Sun; Chenze Li; Ting Yu; Houjuan Zuo; Guanglin Cui; Kun Miao; Chunxia Zhao; Jiangang Jiang; Bettina Heidecker; Olga Barnett; Alan Maisel; Chen Chen; Dao Wen Wang
Journal:  J Am Heart Assoc       Date:  2022-04-04       Impact factor: 6.106

2.  Application of oXiris-continuous hemofiltration adsorption in patients with sepsis and septic shock: A single-centre experience in China.

Authors:  Yanyan Zhou; Chenfang Wu; Lin Ouyang; Ying Peng; Dingming Zhong; Xiaohong Xiang; Jinxiu Li
Journal:  Front Public Health       Date:  2022-09-29
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.