Literature DB >> 33991166

Performance of the faecal immunochemical test for the detection of colorectal neoplasms and the role of proton pump inhibitors in their diagnostic accuracy.

Subashini Chandrapalan1,2, Siew Wan Hee1, Monika M Widlak1,2, Alexia Farrugia1,2, Mohammed T Alam3, Steve Smith4, Ramesh P Arasaradnam1,2,5,6.   

Abstract

AIM: The faecal immunochemical test (FIT) is currently utilized in both symptomatic and screening populations, but little is known about factors that affect its performance. For example, proton pump inhibitor (PPI) therapy has been purported to increase false negative rates. This has significant implications given the extent of PPI prescriptions. The aim of this work was to evaluate the performance of the FIT for the detection of colorectal neoplasms and the impact of PPI therapy on its diagnostic accuracy.
METHOD: Symptomatic patients referred on the suspected cancer pathway and those on polyp surveillance between 2015 and 2019 were approached to participate. Estimates of the accuracy of FIT at different cut-off levels in diagnosing colorectal neoplasms were made. Logistic regression was used to assess the effect of PPIs on the FIT results.
RESULTS: A total of 667 participants were eligible for the final analysis. At a cut-off of 10 μg/g faeces, the overall sensitivity and specificity of FIT for the detection of colorectal cancer (CRC) was 0.85 (95% CI 0.71-0.94) and 0.81 (95% CI 0.78-0.84), respectively. For the detection of advanced neoplasia, the sensitivity was 0.70 (95% CI 0.58-0.79) and the specificity was 0.83 (95% CI 0.80-0.86). At higher thresholds, the sensitivity steadily declined whilst specificity increased. PPI therapy did not have a significant effect on performance of the FIT.
CONCLUSION: FIT is a good rule-out test for the detection of CRC and advanced neoplasia at lower thresholds. PPI therapy does not appear to have an effect on its diagnostic performance.
© 2021 The Authors. Colorectal Disease published by John Wiley & Sons Ltd on behalf of Association of Coloproctology of Great Britain and Ireland.

Entities:  

Keywords:  adenoma; faecal immunochemical test; proton pump inhibitors

Year:  2021        PMID: 33991166     DOI: 10.1111/codi.15735

Source DB:  PubMed          Journal:  Colorectal Dis        ISSN: 1462-8910            Impact factor:   3.788


  2 in total

1.  Faecal immunochemical testing (FIT) in patients with signs or symptoms of suspected colorectal cancer (CRC): a joint guideline from the Association of Coloproctology of Great Britain and Ireland (ACPGBI) and the British Society of Gastroenterology (BSG).

Authors:  Kevin J Monahan; Michael M Davies; Muti Abulafi; Ayan Banerjea; Brian D Nicholson; Ramesh Arasaradnam; Neil Barker; Sally Benton; Richard Booth; David Burling; Rachel Victoria Carten; Nigel D'Souza; James Edward East; Jos Kleijnen; Michael Machesney; Maria Pettman; Jenny Pipe; Lance Saker; Linda Sharp; James Stephenson; Robert Jc Steele
Journal:  Gut       Date:  2022-07-12       Impact factor: 31.793

2.  A Multi-Centre Study to Risk Stratify Colorectal Polyp Surveillance Patients Utilising Volatile Organic Compounds and Faecal Immunochemical Test.

Authors:  Subashini Chandrapalan; Farah Khasawneh; Baljit Singh; Stephen Lewis; James Turvill; Krishna Persaud; Ramesh P Arasaradnam
Journal:  Cancers (Basel)       Date:  2022-10-09       Impact factor: 6.575

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.