Accuracy of a flash glucose monitoring system in cats and determination of the time lag between blood glucose and interstitial glucose concentrations.

Francesca Del Baldo1, Federico Fracassi1, Jully Pires2, Antonio Maria Tardo1, Eleonora Malerba1, Elisa Manassero3, Chen Gilor2,4.   

Abstract

BACKGROUND: The FreeStyle Libre (Abbott Laboratories) is a flash glucose monitoring system (FGMS) that measures interstitial glucose concentration (IG). The system is factory-calibrated, easy to use, inexpensive, and could be useful for monitoring diabetic cats.
OBJECTIVES: To evaluate the analytical and clinical accuracy of the FGMS in cats and establish the lag-time between IG and blood glucose concentration (BG). ANIMALS: Twenty client-owned diabetic cats and 7 purpose-bred healthy cats.
METHODS: Prospective study. Blood glucose concentration was measured using a portable glucose meter validated for use in cats that served as a reference method for IG, as measured by FGMS. In diabetic cats, data were collected for sensor wearing time with different methods of application and accuracy across glycemic ranges. Accuracy was determined by fulfillment of ISO15197:2013 criteria. In healthy cats, lag-time between IG and BG was established after IV administration of exogenous glucose.
RESULTS: Good agreement between IG and BG was obtained (r = .93). Analytical accuracy was not achieved, whereas clinical accuracy was demonstrated with 100% of the results in zones A + B of the Parkes consensus error grid analysis. In the immediate 30 minutes after an IV bolus of glucose, when BG was increasing rapidly (approximately 2%/min), IG increased slowly, resulting in a difference of as much as 579 mg/dL, and no positive correlation between BG and IG was found. CONCLUSIONS AND CLINICAL IMPORTANCE: The FGMS did not fulfill ISO requirements but is sufficiently accurate for glucose monitoring in cats, while considering the lag between IG and BG during periods of rapid changes in BG.
© 2021 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals LLC on behalf of American College of Veterinary Internal Medicine.

Entities:  

Keywords:  FreeStyle Libre; continuous glucose monitoring system; delay; diabetes mellitus; insulin

Year:  2021        PMID: 33991129     DOI: 10.1111/jvim.16122

Source DB:  PubMed          Journal:  J Vet Intern Med        ISSN: 0891-6640            Impact factor:   3.333


  2 in total

1.  Clinical Use of a 180-Day Implantable Glucose Monitoring System in Dogs with Diabetes Mellitus: A Case Series.

Authors:  Antonio Maria Tardo; Concetta Irace; Francesca Del Baldo; Armando Foglia; Federico Fracassi
Journal:  Animals (Basel)       Date:  2022-03-29       Impact factor: 2.752

2.  Evaluation of the FreeStyle Libre, a flash glucose monitoring system, in client-owned cats with diabetes mellitus.

Authors:  Marieke Knies; Erik Teske; Hans Kooistra
Journal:  J Feline Med Surg       Date:  2022-06-28       Impact factor: 1.971

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.