Literature DB >> 33987807

An Interpretable Experimental Data Augmentation Method to Improve Knee Health Classification Using Joint Acoustic Emissions.

Goktug C Ozmen1, Asim H Gazi2, Sevda Gharehbaghi2, Kristine L Richardson2, Mohsen Safaei2, Daniel C Whittingslow3, Sampath Prahalad4, Jennifer L Hunnicutt3, John W Xerogeanes3, Teresa K Snow5, Omer T Inan2.   

Abstract

The characteristics of joint acoustic emissions (JAEs) measured from the knee have been shown to contain information regarding underlying joint health. Researchers have developed methods to process JAE measurements and combined them with machine learning algorithms for knee injury diagnosis. While these methods are based on JAEs measured in controlled settings, we anticipate that JAE measurements could enable accessible and affordable diagnosis of acute knee injuries also in field-deployable settings. However, in such settings, the noise and interference would be greater than in sterile, laboratory environments, which could decrease the performance of existing knee health classification methods using JAEs. To address the need for an objective noise and interference detection method for JAE measurements as a step towards field-deployable settings, we propose a novel experimental data augmentation method to locate and then, remove the corrupted parts of JAEs measured in clinical settings. In the clinic, we recruited 30 participants, and collected data from both knees, totaling 60 knees (36 healthy and 24 injured knees) to be used subsequently for knee health classification. We also recruited 10 healthy participants to collect artifact and joint sounds (JS) click templates, which are audible, short duration and high amplitude JAEs from the knee. Spectral and temporal features were extracted, and clinical data was augmented in five-dimensional subspace by fusing the existing clinical dataset into experimentally collected templates. Then knee scores were calculated by training and testing a linear soft classifier utilizing leave-one-subject-out cross-validation (LOSO-CV). The area under the curve (AUC) was 0.76 for baseline performance without any window removal with a logistic regression classifier (sensitivity = 0.75, specificity = 0.78). We obtained an AUC of 0.86 with the proposed algorithm (sensitivity = 0.80, specificity = 0.89), and on average, 95% of all clinical data was used to achieve this performance. The proposed algorithm improved knee health classification performance by the added information through identification and collection of common artifact sources in JAE measurements. This method when combined with wearable systems could provide clinically relevant supplementary information for both underserved populations and individuals requiring point-of-injury diagnosis in field-deployable settings.
© 2021. Biomedical Engineering Society.

Entities:  

Keywords:  Data augmentation; Knee health; Knee sounds; Machine learning

Mesh:

Year:  2021        PMID: 33987807     DOI: 10.1007/s10439-021-02788-x

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  22 in total

1.  The diagnostic accuracy of ruptures of the anterior cruciate ligament comparing the Lachman test, the anterior drawer sign, and the pivot shift test in acute and chronic knee injuries.

Authors:  J W Katz; R J Fingeroth
Journal:  Am J Sports Med       Date:  1986 Jan-Feb       Impact factor: 6.202

2.  Clinical diagnosis of meniscal tears. Description of a new manipulative test.

Authors:  A F Anderson; A B Lipscomb
Journal:  Am J Sports Med       Date:  1986 Jul-Aug       Impact factor: 6.202

3.  Prospective evaluation of the McMurray test.

Authors:  P J Evans; G D Bell; C Frank
Journal:  Am J Sports Med       Date:  1993 Jul-Aug       Impact factor: 6.202

4.  Epidemiology of 6.6 million knee injuries presenting to United States emergency departments from 1999 through 2008.

Authors:  Brett E Gage; Natalie M McIlvain; Christy L Collins; Sarah K Fields; R Dawn Comstock
Journal:  Acad Emerg Med       Date:  2012-04       Impact factor: 3.451

Review 5.  Osteoarthritis as an outcome of paediatric sport: an epidemiological perspective.

Authors:  Dennis J Caine; Yvonne M Golightly
Journal:  Br J Sports Med       Date:  2011-02-17       Impact factor: 13.800

6.  Adaptive filtering, modelling and classification of knee joint vibroarthrographic signals for non-invasive diagnosis of articular cartilage pathology.

Authors:  S Krishnan; R M Rangayyan; G D Bell; C B Frank; K O Ladly
Journal:  Med Biol Eng Comput       Date:  1997-11       Impact factor: 2.602

7.  A comparison of acute anterior cruciate ligament examinations. Initial versus examination under anesthesia.

Authors:  W F Donaldson; R F Warren; T Wickiewicz
Journal:  Am J Sports Med       Date:  1985 Jan-Feb       Impact factor: 6.202

8.  Acute posterior cruciate ligament injuries.

Authors:  W C Loos; J M Fox; M E Blazina; W Del Pizzo; M J Friedman
Journal:  Am J Sports Med       Date:  1981 Mar-Apr       Impact factor: 6.202

9.  Vibration arthrometry of the knee with torn meniscus: a preliminary report.

Authors:  C C Jiang; Y J Liu; K M Yip; S E Fu; J L Su
Journal:  J Formos Med Assoc       Date:  1994-07       Impact factor: 3.282

10.  Arthroscopy for degenerative knee--a difficult habit to break?

Authors:  Teppo L N Järvinen; Raine Sihvonen; Martin Englund
Journal:  Acta Orthop       Date:  2014-05-21       Impact factor: 3.717

View more