Analysis of the Influence of Peripheral Anatomical Changes for CBCT-Guided Prostate Cancer Radiotherapy.

Yingjie Zhang1, Xiangbin Zhang1, Jing Li1, Liang Zeng2, Xuetao Wang1, Xiaohong Wu3, Yan Li4, Xiaoyu Li1, Renming Zhong1.   

Abstract

PURPOSE: To analyze the influence of the bladder and rectum filling and the body contour changes on the prostate target dose.
METHODS: A total of 190 cone-beam CT (CBCT) image data sets from 16 patients with prostate cancer were used in this study. Dose reconstruction was performed on the virtual CT generated by the deformable planning CT. Then, the effects of the bladder filling, rectal filling, and the patient's body contour changes of the PCTV1 (the prostate area, B1) and PCTV2 (the seminal vesicle area, B2) on the target dose were analyzed. Correlation analysis was performed for the ratio of bladder and rectal volume variation and the variation of the bladder and rectal dose.
RESULTS: The mean Dice coefficients of B1, B2, bladder, and rectum were 0.979, 0.975, 0.888 and 0.827, respectively, and the mean Hausdorff distances were 0.633, 1.505, 2.075, and 1.533, respectively. With the maximum volume variations of 142.04 ml for the bladder and 40.50 ml for the rectum, the changes of V100, V95, D2, and D98 were 1.739 ± 1.762 (%), 0.066 ± 0.169 (%), 0.562 ± 0.442 (%), and 0.496 ± 0.479 (%) in PCTV1 and 1.686 ± 1.051 (%), 0.240 ± 0.215 (%), 1.123 ± 0.925 (%), and 0.924 ± 0.662 (%) in PCTV2, respectively. With a 10% increase in the volume of the bladder and rectum, the V75, V70, and V65 of rectum increased at 0.73 (%), 0.71 (%), and 1.18 (%), and the V75, V70, and V65 of bladder changed at -0.21 (%), -0.32 (%), and -0.39 (%), respectively.
CONCLUSION: Significant correlations were observed between the volume variation and the dose variation of the bladder and rectum. However, when a bladder and rectal filling protocol was adopted, the target dose coverage can be effectively ensured based on CBCT guidance to correct the prostate target position.

Entities:  

Keywords:  CBCT guidance; bladder and rectum filling; body contour changes; dose uncertainty; prostate cancer

Year:  2021        PMID: 33982618     DOI: 10.1177/15330338211016370

Source DB:  PubMed          Journal:  Technol Cancer Res Treat        ISSN: 1533-0338


  1 in total

1.  Evaluating the impact of possible interobserver variability in CBCT-based soft-tissue matching using TCP/NTCP models for prostate cancer radiotherapy.

Authors:  Xiangbin Zhang; Xin Wang; Xiaoyu Li; Li Zhou; Shihong Nie; Changhu Li; Xuetao Wang; Guyu Dai; Zhonghua Deng; Renming Zhong
Journal:  Radiat Oncol       Date:  2022-04-01       Impact factor: 3.481

  1 in total