Literature DB >> 33975095

The influence of age on EEG-based anaesthesia indices.

David P Obert1, Catrin Schweizer1, Sebastian Zinn2, Stephan Kratzer1, Darren Hight3, Jamie Sleigh4, Gerhard Schneider1, Paul S García5, Matthias Kreuzer6.   

Abstract

STUDY
OBJECTIVE: In the upcoming years there will be a growing number of elderly patients requiring general anaesthesia. As age is an independent risk factor for postoperative delirium (POD) the incidence of POD will increase concordantly. One approach to reduce the risk of POD would be to avoid excessively high doses of anaesthetics by using neuromonitoring to guide anaesthesia titration. Therefore, we evaluated the influence of patient's age on various electroencephalogram (EEG)-based anaesthesia indices. DESIGN AND PATIENTS: We conducted an analysis of previously published data by replaying single electrode EEG episodes of maintenance of general anaesthesia from 180 patients (18-90 years; ASA I-IV) into the five different commercially available monitoring systems and evaluated their indices. We included the State/Response Entropy, Narcotrend, qCON/qNOX, bispectral index (BIS), and Treaton MGA-06. For a non-commercial comparison, we extracted the spectral edge frequency (SEF) from the BIS. To evaluate the influence of the age we generated linear regression models. We also assessed the correlation between the various indices. MAIN
RESULTS: During anaesthetic maintenance the values of the SEF, State/Response Entropy, qCON/qNOX and BIS all significantly increased (0.05 Hz/0.19-0.26 index points per year) with the patient's age (p < 0.001); whereas the Narcotrend did not change significantly with age (0.06 index points per year; p = 0.28). The index values of the Treaton device significantly decreased with age (-0.09 index points per year; p < 0.001). These findings were independent of the administered dose of anaesthetics.
CONCLUSIONS: Almost all current neuromonitoring devices are influenced by age, with the potential to result in inappropriately high dosage of anaesthetics. Therefore, anaesthesiologists should be aware of this phenomenon, and the next generation of monitors should correct for these changes.
Copyright © 2021 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Anaesthesia general; Elderly; Electroencephalography; Neuromonitoring; Sevoflurane

Year:  2021        PMID: 33975095     DOI: 10.1016/j.jclinane.2021.110325

Source DB:  PubMed          Journal:  J Clin Anesth        ISSN: 0952-8180            Impact factor:   9.452


  2 in total

1.  Electroencephalogram-Based Evaluation of Impaired Sedation in Patients with Moderate to Severe COVID-19 ARDS.

Authors:  Armin Niklas Flinspach; Sebastian Zinn; Kai Zacharowski; Ümniye Balaban; Eva Herrmann; Elisabeth Hannah Adam
Journal:  J Clin Med       Date:  2022-06-17       Impact factor: 4.964

2.  Evaluation of Anesthetic Specific EEG Dynamics during State Transitions between Loss and Return of Responsiveness.

Authors:  Matthias Kreuzer; Tobias Kiel; Leonie Ernst; Marlene Lipp; Gerhard Schneider; Stefanie Pilge
Journal:  Brain Sci       Date:  2021-12-28
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.