Literature DB >> 33965011

Solid-phase microextraction- probe electrospray ionization devices for screening and quantitating drugs of abuse in small amounts of biofluids.

Milaan Thirukumaran1, Varoon Singh1, Yohei Arao2, Yuka Fujito3, Masayuki Nishimura3, Tairo Ogura2, Janusz Pawliszyn4.   

Abstract

Probe electrospray ionization (PESI) is an ambient ionization mass spectrometry technique (AIMS) that is primarily used in qualitative studies, though researchers have recently combined it with sample preparation for the quantitative analysis of various analytes in biological matrices. This study presents a method that integrates solid-phase microextraction with PESI for direct coupling to a triple quadrupole mass spectrometer, and examines its ability to quantitate drugs of abuse. Intra- and inter-probe reproducibility experiments were conducted to assess the stability and reproducibility of the extraction-phase-coated PESI probes (coating length: 2 mm; coating thickness: 6.5 μm). This research is the first documented instance wherein highly sensitive determinations were successfully attained using these microextraction and micro-desorption techniques in conjunction with small volumes of sample and extraction phase. A mixture consisting of IPA/H2O (1/1 v/v) + 0.1% FA was determined to be the optimal desorption solvent for SPME-PESI-MS/MS, as it facilitated high analyte enrichment in a picolitre of the solvent, which acted at the same time as efficient electrospray media. Furthermore, a method of quantifying drugs of abuse in 30 μL of plasma without matrix modification was also developed. This method had an intra-day accuracy within the 80-120% range for all eight drugs of abuse at concentrations of 3, 30, and 90 pg μL-1; the exception to this result was lorazepam at 30 pg μL-1, which had an intra-day accuracy of 122%. The lower limit of quantification (LLOQ) for fentanyl and nordiazepam was pg μL-1; the LLOQ for buprenorphine, codeine, diazepam, lorazepam, and propranolol was 5 pg μL-1; and the LLOQ of oxazepam was 10 pg μL-1.
Copyright © 2021 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Drugs of abuse; Hydrophilic-lipophilic balance particles; Mass spectrometry; Probe electrospray ionization; Sample preparation; Solid phase microextraction

Mesh:

Substances:

Year:  2021        PMID: 33965011     DOI: 10.1016/j.talanta.2021.122317

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  1 in total

1.  Time-course monitoring of in vitro biotransformation reaction via solid-phase microextraction-ambient mass spectrometry approaches.

Authors:  Karol Jaroch; Janusz Pawliszyn
Journal:  J Pharm Anal       Date:  2021-08-03
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.