Literature DB >> 33963469

Flexing a standard hinge-powered operating table for lumbosacral three-column osteotomy (3-CO) site closure in 84 consecutive patients.

Pierre-Pascal Girod1, Nikolaus Kögl2, Granit Molliqaj3, Sara Lener2, Sebastian Hartmann2, Claudius Thomé2.   

Abstract

Three-column osteotomy (3-CO) is a powerful technique in adult deformity surgery, and pedicle subtraction osteotomy (PSO) is the workhorse to correct severe kyphotic spinal deformities. Aging of the population, increasing cases of iatrogenic flat back deformities and understanding the importance of sagittal balance have led to a dramatic increase of this surgical technique. Surgery, however, is demanding and associated with high complication rates so that every step of the procedure requires meticulous technique. Particularly, osteotomy closure is associated with risks like secondary fracture, translation, or iatrogenic stenosis. This step is traditionally performed by compression or a cantilever maneuver with sometimes excessive forces on the screws or instrumentation. Implant loosening or abrupt subluxation resulting in construct failure and/or neurological deficits can result. The aim of this prospective registry study was to assess the efficacy and safety of our surgical PSO technique as well as the osteotomy closure by flexing a hinge-powered OR table. In a series of 84 consecutive lumbosacral 3-CO, a standardized surgical technique with special focus on closure of the osteotomy was prospectively evaluated. The surgical steps with the patients positioned prone on a soft frame are detailed. Osteotomy closure was achieved by remote controlled bending of a standard OR table without compressive or cantilever forces in all 84 cases. This technique carries a number of advantages, particularly the reversibility and the slow speed of closure with minimum force. There was not a single mechanical intraoperative complication such as vertebral body fracture, subluxation, or adjacent implant loosening during osteotomy closure, compared to external cohorts using the cantilever technique (p = 0.130). The feasibility of controlled 3-CO closure by flexing a standard OR table is demonstrated. This technique enables a safe, gentle closure of the osteotomy site with minimal risk of implant failure or accidental neurological injury.
© 2021. The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.

Entities:  

Keywords:  Deformity surgery; Osteotomy closure technique; Sagittal balance; Surgical PSO technique; VCR

Mesh:

Year:  2021        PMID: 33963469     DOI: 10.1007/s10143-021-01559-5

Source DB:  PubMed          Journal:  Neurosurg Rev        ISSN: 0344-5607            Impact factor:   3.042


  1 in total

1.  Osteotomy of the spine for correction of flexion deformity in rheumatoid arthritis.

Authors:  M N Smith-Petersen; C B Larson; O E Aufranc
Journal:  Clin Orthop Relat Res       Date:  1969 Sep-Oct       Impact factor: 4.176

  1 in total
  1 in total

1.  Domino connector is an efficient tool to improve lumbar lordosis correction angle after pedicle subtraction osteotomy for adult spinal deformity.

Authors:  Anouar Bourghli; Louis Boissiere; Derek Cawley; Daniel Larrieu; Javier Pizones; Ahmet Alanay; Ferran PelIise; Franck Kleinstück; Ibrahim Obeid
Journal:  Eur Spine J       Date:  2022-07-20       Impact factor: 2.721

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.