Catheter-mediated electrical ablation: the relation between current and pulse width on voltage breakdown and shock-wave generation.

G H Bardy1, F Coltorti, R B Stewart, H L Greene, T D Ivey.   

Abstract

Voltage waveform breakdown is characteristic of barotraumatic shock-wave generation during electrical catheter ablation of cardiac arrhythmias. The purpose of this investigation was to avoid barotrauma by defining, in vitro, the limits of pulse amplitude and pulse width for rectangular constant-current pulses that do not result in voltage breakdown and subsequently to determine what pulsing frequency is safe for use when high-energy trains of pulses are used. Electric pulses were delivered with a variable waveform modulator with a wide dynamic range and bandwidth capable of delivering pulses of 30-10,000-mu sec duration with amplitudes of up to 25 A. Cathodal pulses were delivered to a 6F catheter immersed in fresh anticoagulated bovine blood warmed to 37 degrees C to stimulate the milieu of a catheter in the chambers of the human heart. The maximum pulse amplitude that could be delivered without incurring voltage waveform breakdown varied inversely with pulse duration. Pulses of 30 mu sec broke down at currents above 24 A (2,500 V). Pulses of 10,000-mu sec duration broke down at 1 A (250 V). The maximum safely delivered energy for a single pulse was 2.5 J for pulses of 80-120 mu sec. Peak power for single pulses was maximum at 50-55 kW with 30-50-mu sec pulses. Charge delivery for single pulses was maximized at 9 mC with long, 10,000-mu sec duration pulses. To deliver an electrical pulse with energy significantly greater than 2.5 J without incurring voltage breakdown, trains of pulses were delivered where each pulse in the train had previously been shown to be free of voltage breakdown.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1988        PMID: 3396159     DOI: 10.1161/01.res.63.2.409

Source DB:  PubMed          Journal:  Circ Res        ISSN: 0009-7330            Impact factor:   17.367


  7 in total

1.  Cell-attached patch clamp study of the electropermeabilization of amphibian cardiac cells.

Authors:  R J O'Neill; L Tung
Journal:  Biophys J       Date:  1991-05       Impact factor: 4.033

2.  Low energy internal cardioversion of atrial fibrillation resistant to transthoracic shocks.

Authors:  S M Sopher; F D Murgatroyd; A K Slade; I Blankoff; E Rowland; D E Ward; A J Camm
Journal:  Heart       Date:  1996-06       Impact factor: 5.994

Review 3.  Recent Advances in Lesion Formation for Catheter Ablation of Atrial Fibrillation.

Authors:  Adam S Barnett; Tristram D Bahnson; Jonathan P Piccini
Journal:  Circ Arrhythm Electrophysiol       Date:  2016-05

4.  Catheter ablation of ventricular tachycardia.

Authors:  R F Smith; P Ollapally; A Bajaj
Journal:  Trans Am Clin Climatol Assoc       Date:  1989

Review 5.  Atrial fibrillation ablation strategies and technologies: past, present, and future.

Authors:  Thomas J Buist; Douglas P Zipes; Arif Elvan
Journal:  Clin Res Cardiol       Date:  2020-10-22       Impact factor: 5.460

6.  Thermodynamic profiling during irreversible electroporation in porcine liver and pancreas: a case study series.

Authors:  Pierre Agnass; Eran van Veldhuisen; Jantien A Vogel; H Petra Kok; Mark J de Keijzer; Gerben Schooneveldt; Lianne R de Haan; John H Klaessens; Hester J Scheffer; Martijn R Meijerink; Krijn P van Lienden; Thomas M van Gulik; Michal Heger; Johannes Crezee; Marc G Besselink
Journal:  J Clin Transl Res       Date:  2020-03-12

7.  Two decades of implantable cardioverter defibrillator implantation and follow-up at a South African referral centre: trends, indications and long-term outcomes in a resource-limited setting.

Authors:  Philasande Mkoko; Kayla Solomon; Ashley Chin
Journal:  Int J Arrhythmia       Date:  2022-08-01
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.