| Literature DB >> 33957918 |
Anna Kaoutskaia1,2, Mohammed Shurrab3, Guy Amit4, Ratika Parkash5, Derek Exner6, Satish Toal7, Laurence Sterns8, Jean-Francois Sarrazin9, Vijay Chauhan10, Omar Sultan11, Girish Nair12, Marc Deyell13, Laurent Macle14, Steve Klassen15, Benedict Glover16, Eugene Crystal16.
Abstract
BACKGROUND/Entities:
Keywords: Arrhythmia; Cardiac catheter ablation; Invasive electrophysiology; Registry; Survey
Mesh:
Year: 2021 PMID: 33957918 PMCID: PMC8101210 DOI: 10.1186/s12913-021-06441-0
Source DB: PubMed Journal: BMC Health Serv Res ISSN: 1472-6963 Impact factor: 2.655
Facility Resource Information
| 2015–2016 | 2013–2014 | 2011–2012 | |
|---|---|---|---|
| N (%) | N (%) | N (%) | |
| University Affiliated Hospitals | 14 (100 %) | 14 (100 %) | 17 (89 %) |
| Lab Infrastructure | |||
| Centers: Implants done in OR | 4 (29 %) | 6 (43 %) | 8 (47 %) |
| Ablation rooms | 1.9 (1–4)a | 1.8 (1–3)a | 1.6 (1–3)a |
| Days/Week Room used for Ablationc | 7.0 (2–14)a | 7.1 (2–14)a | 5.3 (1–13)a |
| Implant Days/Weekc | 3.4 (0–5)a | 3.2 (0–5)a | 3.25 (1–6)a |
| EP Procedures Performed | |||
| Diagnostic EP Procedures | 14 (100 %) | 14 (100 %) | 19 (100 %) |
| RF | 14 (100 %) | 13 (93 %) | 19 (100 %) |
| Contact Force | 14 (100 %) | n/a | n/a |
| Cryoablation point-by-point | 12 (86 %) | 9 (64 %) | n/a |
| Cryoballoon | 10 (71 %) | 6 (43 %) | 15 (83 %) |
| PVAC | 3 (21 %) | 4 (29 %) | n/a |
| NMARQ (circular RF) | 2 (14 %) | 0 | n/a |
| Mapping Systems | |||
| CARTO | 12 (86 %) | 13 (93 %) | 14 (78 %) |
| Intracardiac echo | 12 (86 %) | 12 (86 %) | 14 (78 %) |
| EnSite-NavX Velocity | 10 (71 %) | 13 (93 %) | 15 (83 %) |
| EnSite-NavX Precision | 8 (57 %) | n/a | n/a |
| Mediguide | 2 (14 %) | 2 (14 %) | n/a |
| Rhythmia™ | 1 (7 %) | 0 | n/a |
| LocaLisa | 1 (7 %) | 1 (7 %) | 1 (6 %) |
| STXS | 2 (14 %) | 1 (7 %) | 2 (11 %) |
| Imaging Systemsb | |||
| General Electric | 1 (7 %) | 1 (7 %) | n/a |
| Philips | 8 (57 %) | 8 (57 %) | n/a |
| Siemens | 6 (43 %) | 7 (50 %) | n/a |
| Toshiba | 2 (14 %) | 2 (14 %) | n/a |
| Portable GE | 1 (7 %) | 1 (7 %) | n/a |
a = range
b = present in number of centres
c = days per week room used for ablation x number of rooms
EP Laboratories Personnel data
| 2015–2016 | 2013–2014 | 2011–2012 | ||||||
|---|---|---|---|---|---|---|---|---|
| Mean | Range | Mean | Range | Mean | Range | |||
| Full Time physicians per centre | 4.1 | (0–7) | 4.1 | (1–7) | 3.5 | (0–7) | ||
| Part Time physicians per centre | 1.6 | (0–12) | 1.2 | (0–5) | 1.1 | (0–7) | ||
| Trainees per centre | 2.5 | (0–6) | 2.9 | (0–7) | 2.7 | (0–5) | ||
| Nurses trained specifically for EP | 4.6 | (0–10) | 4.4 | (0–10) | n/a | |||
| Permanent EP RN’s | 3.0 | (0–7) | 2.5 | (0–6) | n/a | |||
| EP technicians | 1.5 | (0–6) | 1.4 | (0–7) | n/a | |||
| Non- 3D mapping systems operated by: N(%)a | ||||||||
| EP technicians | 3 (21 %) | 2.5 (18 %) | 9 (50 %) | |||||
| EP nurses | 7 (50 %) | 7 (50 %) | 7 (39 %) | |||||
| Industry Reps | 4 (29 %) | 4.5 (32 %) | 2 (11 %) | |||||
asums of totals, and percentage of total
Fig. 1Annual number of ablations per centre in the eleven centres participating in all survey instalments: 2011–2016
Fig. 2Ablations per operator in the eleven centres participating in all surveys: 2011–2016
Volume of Ablation procedures by substrate 2011–2016 reported as percentage of total respondents
| 2015–2016 | 2013–2014 | 2011–2012 | |
|---|---|---|---|
| Atrial Fibrillation/Atypical Flutter | 36 % | 32 % | 30 % |
| AV Nodal Re-entry Tachycardia | 18 % | 22 % | 23 % |
| Typical flutter | 17 % | 16 % | 21 % |
| AV Reciprocal Tachycardia | 10 % | 10 % | 11 % |
| Atrial Tachycardia | 3 % | 4 % | 6 % |
| Atrioventricular Junction | 7 % | 8 % | n/a |
| Ventricular Tachycardia | 8 % | 7 % | 9 % |
| Total annual ablations in 11 consistently respondent centres | 5478 | 5243 | 4908 |
AV atrioventricular
Procedural and infrastructure data as it pertains to ablation of Atrial Fibrillation arrhythmia
| 2016 | 2015 | 2014 | 2013 | |
|---|---|---|---|---|
| Paroxysmal AF | 55a | 58a | 84a | 93a |
| Redo cases | 22 % | 15 % | 15 % | 22 % |
| Chronic success | 71 % | 71 % | 69 % | 69 % |
| Non-Paroxysmal AF | 47a | 42a | 34a | 29a |
| Redo cases | 17 % | 22 % | 21 % | 28 % |
| Chronic success | 60 % | 62 % | 90 % | 85 % |
| Manual | 100 % | 100 % | 100 % | 100 % |
| STXS | 17 % | 13 % | 17 % | 17 % |
| NMARQ (RF) | 17 % | 13 % | 0 % | 0 % |
| RF irrigated | 100 % | 100 % | 100 % | 100 % |
| RF non-irrigated | 33 % | 25 % | 0 % | 0 % |
| Cryoballoon | 100 % | 88 % | 33 % | 33 % |
| Arctic Front | 100 % | 75 % | 44 % | 33 % |
| Contact Force | 100 % | 100 % | n/a | n/a |
| PVAC | 17 % | 25 % | 22 % | 33 % |
* average annual procedures per year