Development of the Soft X-ray AGM-AGS RIXS beamline at the Taiwan Photon Source.

A Singh1, H Y Huang1, Y Y Chu1, C Y Hua1, S W Lin1, H S Fung1, H W Shiu1, J Chang1, J H Li2, J Okamoto1, C C Chiu1, C H Chang1, W B Wu1, S Y Perng1, S C Chung1, K Y Kao1, S C Yeh1, H Y Chao1, J H Chen1, D J Huang1, C T Chen1.   

Abstract

We report on the development of a high-resolution and highly efficient beamline for soft X-ray resonant inelastic X-ray scattering (RIXS) located at the Taiwan Photon Source. This beamline adopts an optical design that uses an active grating monochromator (AGM) and an active grating spectrometer (AGS) to implement the energy compensation principle of grating dispersion. Active gratings are utilized to diminish defocus, coma and higher-order aberrations, as well as to decrease the slope errors caused by thermal deformation and optical polishing. The AGS is mounted on a rotatable granite platform to enable momentum-resolved RIXS measurements with scattering angles over a wide range. Several high-precision instruments developed in-house for this beamline are described briefly. The best energy resolution obtained from this AGM-AGS beamline was 12.4 meV at 530 eV, achieving a resolving power of 4.2 × 104, while the bandwidth of the incident soft X-rays was kept at 0.5 eV. To demonstrate the scientific impact of high-resolution RIXS, we present an example of momentum-resolved RIXS measurements on a high-temperature superconducting cuprate, i.e. La2-xSrxCuO4. The measurements reveal the A1g buckling phonons in superconducting cuprates, opening a new opportunity to investigate the coupling between these phonons and charge-density waves. open access.

Entities:  

Keywords:  active grating; grating monochromator; resonant inelastic X-ray scattering; soft X-ray beamline; soft X-ray optics; soft X-ray spectra

Year:  2021        PMID: 33950006     DOI: 10.1107/S1600577521002897

Source DB:  PubMed          Journal:  J Synchrotron Radiat        ISSN: 0909-0495            Impact factor:   2.616


  1 in total

1.  I21: an advanced high-resolution resonant inelastic X-ray scattering beamline at Diamond Light Source.

Authors:  Ke Jin Zhou; Andrew Walters; Mirian Garcia-Fernandez; Thomas Rice; Matthew Hand; Abhishek Nag; Jiemin Li; Stefano Agrestini; Peter Garland; Hongchang Wang; Simon Alcock; Ioana Nistea; Brian Nutter; Nicholas Rubies; Giles Knap; Martin Gaughran; Fajin Yuan; Peter Chang; John Emmins; George Howell
Journal:  J Synchrotron Radiat       Date:  2022-02-22       Impact factor: 2.616

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.