Literature DB >> 33940883

Numerical study on lung ultrasound B-line formation as a function of imaging frequency and alveolar geometries.

Emanuele Peschiera1, Federico Mento1, Libertario Demi1.   

Abstract

Lung ultrasound (LUS) has become a widely adopted diagnostic method for several lung diseases. However, the presence of air inside the lung does not allow the anatomical investigation of the organ. Therefore, LUS is mainly based on the interpretation of vertical imaging artifacts, called B-lines. These artifacts correlate with several pathologies, but their genesis is still partly unknown. Within this framework, this study focuses on the factors affecting the artifacts' formation by numerically simulating the ultrasound propagation within the lungs through the toolbox k-Wave. Since the main hypothesis behind the generation of B-lines relies on multiple scattering phenomena occurring once acoustic channels open at the lung surface, the impact of changing alveolar size and spacing is of interest. The tested domain is of size 4 cm × 1.6 cm, the investigated frequencies vary from 1 to 5 MHz, and the explored alveolar diameters and spacing range from 100 to 400 μm and from 20 to 395 μm, respectively. Results show the strong and entangled relation among the wavelength, the domain geometries, and the artifact visualization, allowing for better understanding of propagation in such a complex medium and opening several possibilities for future studies.

Entities:  

Year:  2021        PMID: 33940883     DOI: 10.1121/10.0003930

Source DB:  PubMed          Journal:  J Acoust Soc Am        ISSN: 0001-4966            Impact factor:   1.840


  3 in total

1.  All B-lines are equal, but some B-lines are more equal than others.

Authors:  Andrea Boccatonda; Giulio Cocco; Damiano D'Ardes; Susanna Vicari; Cosima Schiavone
Journal:  J Ultrasound       Date:  2022-06-28

Review 2.  State of the Art in Lung Ultrasound, Shifting from Qualitative to Quantitative Analyses.

Authors:  Federico Mento; Umair Khan; Francesco Faita; Andrea Smargiassi; Riccardo Inchingolo; Tiziano Perrone; Libertario Demi
Journal:  Ultrasound Med Biol       Date:  2022-09-22       Impact factor: 3.694

3.  Diagnostic Value of Color Doppler Ultrasonography in Subacute Thyroiditis.

Authors:  Yonggang Chen; Shulan Zhu; Huabin Chen; Liting Yao; Jingmian Zhou; Yi Xu; Biqin Lin; Xiaoping Chen
Journal:  Scanning       Date:  2022-09-17       Impact factor: 1.750

  3 in total