| Literature DB >> 33937421 |
Abstract
OBJECTIVE: To determine the sensitivity, specificity and accuracy of ultrasound to diagnose the patients with tendon rupture of upper extremity referred to Taleghani Hospital's center of Kermanshah in 2019.Entities:
Keywords: Sensitivity; Specificity.; Tendon injuries; Ultrasound
Year: 2021 PMID: 33937421 PMCID: PMC8062890 DOI: 10.30476/BEAT.2021.85570
Source DB: PubMed Journal: Bull Emerg Trauma ISSN: 2322-2522
Frequency distribution of under study patients by gender and age groups
|
|
| |
|---|---|---|
| Gender | ||
| 98 | 86.7 | Male |
| 15 | 13.3 | Female |
| Age group | ||
| 6 | 5.3 | Less than 20 years |
| 41 | 36.3 | 21-30 years old |
| 62 | 54.9 | 31-40 years old |
| 4 | 3.5 | More than 40 years |
Fig. 1Frequency (Percentage) of studied patients by type of examined tendon. FCR&U,Flexor Carpi Radialis & Ulnaris ; Extensor; ECRL&B, Extensor Carpi Radialis Longus & Brevis; APL, Abductor Pollicis Longus FDP, Flexor Digitorum Profundus; FDS,Flexor Digitorum Superficialist ; F3&4,Flexor 3،4;E5, Extensor5
Comparison of surgical findings and ultrasound findings in terms of Complete Rupture
|
| ||||
|---|---|---|---|---|
|
|
|
| ||
| 45 | 10 | 55 | Complete Rupture | Ultrasound Findings |
| 7 | 26 | 33 | Without Rupture | |
| 52 | 36 | Total | ||
Estimations of ultrasound diagnostic value in detecting of complete tendon rupture
|
|
| |
|---|---|---|
| 86.5 | 94.4– 74.2 | Sensitivity |
| 72.2 | 8.85 – 54.8 | Specificity |
| 81.8 | 88.5 – 72.4 | Positive predictive value |
| 78.9 | 88.4 –64.4 | Negative predictive value |
| 80.1 | 88.3 – 70.9 | Accuracy |
Comparison of surgical findings and ultrasound findings in terms of Rupture (Complete or Partial)
|
| ||||
|---|---|---|---|---|
|
|
|
| ||
| 73 | 10 | 83 | With Rupture | Ultrasound Findings |
| 4 | 26 | 30 | Without Rupture | |
| 77 | 36 | Total | ||
Estimates of ultrasound diagnostic value in detecting tendon rupture (complete or partial)
|
|
| |
|---|---|---|
| 94.8 | 98.6 – 87.2 | Sensitivity |
| 72.2 | 85.8–54.8 | Specificity |
| 87.9 | 92.5– 81.1 | Positive predictive value |
| 86.7 | 5.94 –72.0 | Negative predictive value |
| 87.6 | 1.93 – 80.1 | Accuracy |