Our clinical case supports the effectiveness of distal His-Bundle pacing in obtaining ventricular resynchronization in patients with LBBB and left ventricular dysfunction, particularly in the context of post-TAVI conduction disturbances.Entities:
Keywords: TAVI; cardiac resynchronization therapy; his‐bundle pacing; left bundle branch block
Year: 2021 PMID: 33936673 PMCID: PMC8077332 DOI: 10.1002/ccr3.4000
Source DB: PubMed Journal: Clin Case Rep ISSN: 2050-0904
FIGURE 1Baseline ECG tracing, showing complete left bundle brunch block (QRS width 150 mseg)
FIGURE 2Intracardiac recording (with the pacing lead), depicting the intrahisian conduction delay (splitting of the His potential)
FIGURE 3Fluoroscopy image showing the final position of the pacing leads. His lead (white arrow)
FIGURE 4ECG tracing showing ventricular pacing with His‐bundle capture (nonselective) and QRS width of 90 ms