Literature DB >> 33931788

[Micropulse cyclophotocoagulation lowers the intraocular pressure: half year results].

Andrea Huth1, Arne Viestenz.   

Abstract

BACKGROUND: Cyclophotocoagulation (CPC) is a simple noninvasive and quickly available procedure for lowering intraocular pressure but due to its dreaded potential for complications it continues to play an outsider role in surgical treatment planning. The Micropulse-CPC promises to be a more tissue-friendly and less painful procedure and thus a lower rate of side effects.
METHOD: Retrospective evaluation of all patients who were treated with the Micropulse-CPC laser at the measurement times 1 day preoperatively, 2 days postoperatively, after 3 months and 6 months.
RESULTS: Between 2018 and 2019 a total of 63 eyes in 46 patients were treated. The mean intraocular pressure in the total collective was 20.6 mm Hg before surgery and decreased to 13.5 mm Hg 2 days after surgery, 16.2 mm Hg after 3 months and 14.6 mm Hg after 6 months (p < 0.002). An average of 3.2 hypotensive substances were used preoperatively, 2.4 substances 2 days postoperatively, 2.6 substances after 3 months and 2.8 after 6 months (p < 0.001). The visual acuity (VA) before surgery was 0.59 logMAR, 2 days postoperatively VA was 0.60, after 3 months 0.59 and after 6 months VA was 0.5 (statistically not significant). A complication (subconjunctival bleeding) occurred intraoperatively and the postoperative complication rate was 0%.
CONCLUSION: Treatment with a Micropulse-CPC laser offers a gentle way of reducing pressure in a timely manner. The use of the Micropulse-CPC is advocated as a first surgical option as well as for patients with good visual acuity.
© 2021. Springer Medizin Verlag GmbH, ein Teil von Springer Nature.

Entities:  

Keywords:  Complication rate; Glaucoma; Micropulse-CPC; Pain; Visual acuity

Mesh:

Year:  2021        PMID: 33931788     DOI: 10.1007/s00347-021-01391-8

Source DB:  PubMed          Journal:  Ophthalmologe        ISSN: 0941-293X            Impact factor:   1.059


  8 in total

1.  Treatment outcomes in the Tube Versus Trabeculectomy (TVT) study after five years of follow-up.

Authors:  Steven J Gedde; Joyce C Schiffman; William J Feuer; Leon W Herndon; James D Brandt; Donald L Budenz
Journal:  Am J Ophthalmol       Date:  2012-01-15       Impact factor: 5.258

2.  Transscleral diode laser cycloablation in patients with good vision.

Authors:  A P Rotchford; R Jayasawal; S Madhusudhan; S Ho; A J King; S A Vernon
Journal:  Br J Ophthalmol       Date:  2010-06-24       Impact factor: 4.638

3.  Clinical Efficacy and Safety Profile of Micropulse Transscleral Cyclophotocoagulation in Refractory Glaucoma.

Authors:  Alice L Williams; Marlene R Moster; Kamran Rahmatnejad; Arthur F Resende; Teresa Horan; Michael Reynolds; Edward Yung; Benjamin Abramowitz; Sarah Kuchar; Michael Waisbourd
Journal:  J Glaucoma       Date:  2018-05       Impact factor: 2.503

4.  Prospective evaluation of micropulse transscleral diode cyclophotocoagulation in refractory glaucoma: 1 year results.

Authors:  Alessandro Adad Jammal; Danilo Campos Costa; José Paulo Cabral Vasconcellos; Vital Paulino Costa
Journal:  Arq Bras Oftalmol       Date:  2019-06-27       Impact factor: 0.872

5.  Outcomes of Micropulse Transscleral Cyclophotocoagulation in Uncontrolled Glaucoma Patients.

Authors:  Karen Zaarour; Youssef Abdelmassih; Nicolas Arej; Georges Cherfan; Karim F Tomey; Ziad Khoueir
Journal:  J Glaucoma       Date:  2019-03       Impact factor: 2.503

6.  Micropulse Cyclophotocoagulation: Initial Results in Refractory Glaucoma.

Authors:  Matthew E Emanuel; Davinder S Grover; Ronald L Fellman; David G Godfrey; Oluwatosin Smith; Michelle R Butler; Helen L Kornmann; William J Feuer; Swati Goyal
Journal:  J Glaucoma       Date:  2017-08       Impact factor: 2.503

Review 7.  Cyclodestructive Procedures in Glaucoma: A Review of Current and Emerging Options.

Authors:  Anna I Dastiridou; Andreas Katsanos; Philippe Denis; Brian A Francis; Dimitrios G Mikropoulos; Miguel A Teus; Anastasios-Georgios Konstas
Journal:  Adv Ther       Date:  2018-11-17       Impact factor: 3.845

8.  IRIDEX MicroPulse P3: innovative cyclophotocoagulation.

Authors:  M Monica Gavris; Ioana Olteanu; Erzsebet Kantor; Radu Mateescu; Roxana Belicioiu
Journal:  Rom J Ophthalmol       Date:  2017 Apr-Jun
  8 in total
  1 in total

1.  Efficacy and safety of high-intensity focused ultrasound cyclo-plasty in glaucoma.

Authors:  Di Chen; Xiu-Juan Guo; Shu-Ke Luo; Yan Lu; Xiu-Rong Tang
Journal:  BMC Ophthalmol       Date:  2022-10-07       Impact factor: 2.086

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.