Literature DB >> 33922543

Accuracy and Reproducibility of Facial Measurements of Digital Photographs and Wrapped Cone Beam Computed Tomography (CBCT) Photographs.

Maged Sultan Alhammadi1, Abeer Abdulkareem Al-Mashraqi2, Rayid Hussain Alnami3, Nawaf Mohammad Ashqar3, Omar Hassan Alamir3, Esam Halboub2,4, Rodolfo Reda5, Luca Testarelli5, Shankargouda Patil6.   

Abstract

The study sought to assess whether the soft tissue facial profile measurements of direct Cone Beam Computed Tomography (CBCT) and wrapped CBCT images of non-standardized facial photographs are accurate compared to the standardized digital photographs. In this cross-sectional study, 60 patients with an age range of 18-30 years, who were indicated for CBCT, were enrolled. Two facial photographs were taken per patient: standardized and random (non-standardized). The non-standardized ones were wrapped with the CBCT images. The most used soft tissue facial profile landmarks/parameters (linear and angular) were measured on direct soft tissue three-dimensional (3D) images and on the photographs wrapped over the 3D-CBCT images, and then compared to the standardized photographs. The reliability analysis was performed using concordance correlation coefficients (CCC) and depicted graphically using Bland-Altman plots. Most of the linear and angular measurements showed high reliability (0.91 to 0.998). Nevertheless, four soft tissue measurements were unreliable; namely, posterior gonial angle (0.085 and 0.11 for wrapped and direct CBCT soft tissue, respectively), mandibular plane angle (0.006 and 0.0016 for wrapped and direct CBCT soft tissue, respectively), posterior facial height (0.63 and 0.62 for wrapped and direct CBCT soft tissue, respectively) and total soft tissue facial convexity (0.52 for both wrapped and direct CBCT soft tissue, respectively). The soft tissue facial profile measurements from either the direct 3D-CBCT images or the wrapped CBCT images of non-standardized frontal photographs were accurate, and can be used to analyze most of the soft tissue facial profile measurements.

Entities:  

Keywords:  cone beam computed tomography; facial photographs; standardized photograph; wrapped photographs

Year:  2021        PMID: 33922543     DOI: 10.3390/diagnostics11050757

Source DB:  PubMed          Journal:  Diagnostics (Basel)        ISSN: 2075-4418


  15 in total

1.  Accuracy of 3D Facial Models Obtained from CBCT Volume Wrapping.

Authors:  Pratik Premjani; Anas Hasan Al-Mulla; Donald J Ferguson
Journal:  J Clin Orthod       Date:  2015-10

2.  Accuracy and reliability of 3D stereophotogrammetry: A comparison to direct anthropometry and 2D photogrammetry.

Authors:  Furkan Dindaroğlu; Pınar Kutlu; Gökhan Serhat Duran; Serkan Görgülü; Erhan Aslan
Journal:  Angle Orthod       Date:  2015-08-12       Impact factor: 2.079

3.  Accuracy of measurements of mandibular anatomy in cone beam computed tomography images.

Authors:  John B Ludlow; William Stewart Laster; Meit See; L'Tanya J Bailey; H Garland Hershey
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2006-08-04

4.  Repeatability Study of Angular and Linear Measurements on Facial Morphology Analysis by Means of Stereophotogrammetry.

Authors:  Lilian Mendes Andrade; Ana Maria Bettoni Rodrigues da Silva; Laís Valencise Magri; Marco Antônio Moreira Rodrigues da Silva
Journal:  J Craniofac Surg       Date:  2017-06       Impact factor: 1.046

5.  Superimposition of a cone beam computed tomography (CBCT) scan and a photograph: A dental technique.

Authors:  Soo Young Lee; Heechul Kim; Doyun Lee; Chan Park
Journal:  J Prosthet Dent       Date:  2020-03-09       Impact factor: 3.426

6.  Photographic Assessment of Cephalometric Measurements in Skeletal Class II Cases: A Comparative Study.

Authors:  Pooja Mehta; Roshan M Sagarkar; Silju Mathew
Journal:  J Clin Diagn Res       Date:  2017-06-01

7.  A three-dimensional soft tissue analysis of fifteen patients with Class II, Division 1 malocclusions after bimaxillary surgery.

Authors:  J P Moss; A M McCance; W R Fright; A D Linney; D R James
Journal:  Am J Orthod Dentofacial Orthop       Date:  1994-05       Impact factor: 2.650

8.  Diagnostic concordance between skeletal cephalometrics, radiograph-based soft-tissue cephalometrics, and photograph-based soft-tissue cephalometrics.

Authors:  Riccardo Nucera; Antonino Lo Giudice; Mirea Bellocchio; Paola Spinuzza; Alberto Caprioglio; Giancarlo Cordasco
Journal:  Eur J Orthod       Date:  2017-08-01       Impact factor: 3.075

9.  Photographic assessment of cephalometric measurements.

Authors:  Liliane de Carvalho Rosas Gomes; Karla Orfelina Carpio Horta; Luiz Gonzaga Gandini; Marcelo Gonçalves; João Roberto Gonçalves
Journal:  Angle Orthod       Date:  2013-04-18       Impact factor: 2.079

10.  Accuracy and reliability of 2-dimensional photography versus 3-dimensional soft tissue imaging.

Authors:  Irem Ayaz; Eman Shaheen; Medhat Aly; Sohaib Shujaat; Giulia Gallo; Wim Coucke; Constantinus Politis; Reinhilde Jacobs
Journal:  Imaging Sci Dent       Date:  2020-03-17
View more
  15 in total

1.  Modeling and Simulating an Orthodontic System Using Virtual Methods.

Authors:  Stelian-Mihai-Sever Petrescu; Mihaela Jana Țuculină; Dragoș Laurențiu Popa; Alina Duță; Alex Ioan Sălan; Ruxandra Voinea Georgescu; Oana Andreea Diaconu; Adina Andreea Turcu; Horia Mocanu; Andreea Gabriela Nicola; Ionela Teodora Dascălu
Journal:  Diagnostics (Basel)       Date:  2022-05-23

2.  Postoperative Complications in Genioplasty and Their Association with Age, Gender, and Type of Genioplasty.

Authors:  Muslim Khan; Nigam Sattar; Mahwish Erkin
Journal:  Int J Dent       Date:  2021-11-17

3.  Innovations in Diagnostic Imaging in Oral and Maxillofacial Diseases.

Authors:  Maurilio D'Angelo; Alessio Zanza; Dario Di Nardo; Luca Testarelli
Journal:  Diagnostics (Basel)       Date:  2022-02-19

4.  Assessment of Anterior Loop of Inferior Alveolar Nerve and Its Anatomic Variations with Age, Gender, and Dentition Status in Indian Population: A CBCT Study.

Authors:  Anjali Gupta; Sandeep Kumar; Siddharth Kumar Singh; Arunoday Kumar; Abhishek Gupta; Palkin Mehta
Journal:  Int J Dent       Date:  2021-08-31

5.  Comparison of the Accuracy of Fixture-Level Implant Impression Making with Different Splinting Techniques.

Authors:  Mehrdad Nateghi; Ramin Negahdari; Sahar Molaei; Ali Barzegar; Sepideh Bohlouli
Journal:  Int J Dent       Date:  2021-10-14

6.  Titanium dioxide dental implants surfaces related oxidative stress in bone remodeling: a systematic review.

Authors:  Elaf Akram Abdulhameed; Natheer H Al-Rawi; Marzuki Omar; Nadia Khalifa; A B Rani Samsudin
Journal:  PeerJ       Date:  2022-03-03       Impact factor: 2.984

7.  A Novel Approach for Dynamic (4d) Multi-View Stereo System Camera Network Design.

Authors:  Piotr Osiński; Jakub Markiewicz; Jarosław Nowisz; Michał Remiszewski; Albert Rasiński; Robert Sitnik
Journal:  Sensors (Basel)       Date:  2022-02-17       Impact factor: 3.576

8.  Three-dimensional evaluation of soft tissues in hyperdivergent skeletal class II females in Guangdong.

Authors:  Xueqin Zhang; Jinxuan Zheng; Jianqing Deng; Zhaoxiang Wen; Zhengyuan Chen; Liyi Gan; Liping Wu
Journal:  BMC Med Imaging       Date:  2022-03-29       Impact factor: 1.930

Review 9.  Evaluation of Electromyographic Activity of Masticatory Muscles in Adults with Posterior Crossbite.

Authors:  Luiz Makito Osawa Gutierrez; Melissa Coradini Quatrin; Chiarella Sforza; Rafael Reimann Baptista; Eduardo Martinelli Santayana de Lima
Journal:  Int J Dent       Date:  2022-03-12

Review 10.  Diagnostic Accuracy of CBCT for Detection of Second Canal of Permanent Teeth: A Systematic Review and Meta-Analysis.

Authors:  Nyan M Aung; Kyaw K Myint
Journal:  Int J Dent       Date:  2021-07-20
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.