Literature DB >> 3391919

A theoretical analysis of interrupter technique for measuring respiratory mechanics.

J H Bates1, P Baconnier, J Milic-Emili.   

Abstract

The application of the flow interrupter technique to series and parallel models of the respiratory system is examined theoretically, assuming instantaneous transmission of pressures and incompressible gases in the lung air spaces. The initial pressure change observed immediately after occlusion divided by the preocclusion flow gives an initial resistance (Rinit) equal to that of the airway tree when the model consists of compartments connected in parallel. When the compartments are connected in series, Rinit is the resistance of the most proximal airway only. In general, the initial pressure change is followed by a second slower change, reflecting equilibration of pressures between the compartments. The total postocclusion pressure change divided by the flow gives a steady-state resistance (Rss) whose value depends on the ventilation history before occlusion. When this history consists of a relaxed expiration Rss asymptotes from Rinit to a value higher than the zero-frequency resistance of the model as the expiratory time increases. However, the relative contributions of serial and parallel pendelluft and viscoelasticity to Rss cannot be determined from pressure and flow measurements made at the airway opening. Therefore in disease, the interrupter method does not permit one to say whether ventilation inhomogeneity or alteration in lung tissue properties is the predominant abnormality.

Entities:  

Mesh:

Year:  1988        PMID: 3391919     DOI: 10.1152/jappl.1988.64.5.2204

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  19 in total

1.  A new approach to mechanical simulation of lung behaviour: pressure-controlled and time-related piston movement.

Authors:  A F Verbraak; P R Rijnbeek; J E Beneken; J M Bogaard; A Versprille
Journal:  Med Biol Eng Comput       Date:  2001-01       Impact factor: 2.602

2.  Elastic pressure-volume curves: what information do they convey?

Authors:  B Jonson; C Svantesson
Journal:  Thorax       Date:  1999-01       Impact factor: 9.139

3.  Determination of rate-constants as a method to describe passive expiration.

Authors:  Fabrizio Locchi; Gian-Luca Chelucci; Walter Araujo Zin
Journal:  Eur J Appl Physiol       Date:  2003-08-05       Impact factor: 3.078

4.  Respiratory mechanical properties during fentanyl and alfentanil anaesthesia.

Authors:  P P Ruiz Neto; J O Auler Júnior
Journal:  Can J Anaesth       Date:  1992-05       Impact factor: 5.063

5.  Remembrance of weaning past: the seminal papers.

Authors:  Martin J Tobin
Journal:  Intensive Care Med       Date:  2006-08-08       Impact factor: 17.440

6.  Measurement of respiratory system resistance during mechanical ventilation.

Authors:  Claude Guerin; Jean-Christophe Richard
Journal:  Intensive Care Med       Date:  2007-04-25       Impact factor: 17.440

7.  Measuring time-varying respiratory mechanics during anesthesia.

Authors:  Jiro Sato; Rie Kato; Norihiro Shinozuka; Tadanobu Mizuguchi
Journal:  J Anesth       Date:  1995-06       Impact factor: 2.078

8.  Pattern of lung emptying and expiratory resistance in mechanically ventilated patients with chronic obstructive pulmonary disease.

Authors:  Eumorfia Kondili; Christina Alexopoulou; George Prinianakis; Nectaria Xirouchaki; Dimitris Georgopoulos
Journal:  Intensive Care Med       Date:  2004-03-31       Impact factor: 17.440

9.  Intravenous glutamine decreases lung and distal organ injury in an experimental model of abdominal sepsis.

Authors:  Gisele P Oliveira; Mariana B G Oliveira; Raquel S Santos; Letícia D Lima; Cristina M Dias; Alexandre M Ab' Saber; Walcy R Teodoro; Vera L Capelozzi; Rachel N Gomes; Patricia T Bozza; Paolo Pelosi; Patricia R M Rocco
Journal:  Crit Care       Date:  2009-05-19       Impact factor: 9.097

10.  Pressure-dependent stress relaxation in acute respiratory distress syndrome and healthy lungs: an investigation based on a viscoelastic model.

Authors:  Steven Ganzert; Knut Möller; Daniel Steinmann; Stefan Schumann; Josef Guttmann
Journal:  Crit Care       Date:  2009-12-09       Impact factor: 9.097

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.