Literature DB >> 33914206

Flow analysis during mock circulation in normal and aortic arch aneurysm models through an aortic cannula toward the aortic arch and root.

Takeshi Goto1, Ikuo Fukuda2, Takao Inamura3, Minori Shirota3, Masahito Minakawa4.   

Abstract

The aim of this study was to elucidate flow patterns of two different types of aortic cannulas inserted from the ascending aorta toward the aortic arch and root by mock circulation in a normal aortic arch and an aortic arch aneurysm model. Extracorporeal circulation was established using a centrifugal pump, a transparent glass normal aortic arch model, and an aortic arch aneurysm model for measurement by particle image velocimetry. The Stealthflow and Dispersion cannulas were used to elucidate the characteristics of the flow pattern and velocity under the condition of the cannula tip toward the aortic arch and aortic root. In the normal aortic arch model, high-velocity exit flow ranging from 0.7 to 0.8 m/s was detected in the proximal aortic arch by directing the cannula tip toward the aortic arch, whereas flow velocity in the aortic arch was < 0.2 m/s by directing the cannula tip toward the aortic root. In the aortic arch aneurysm model, high-velocity exit flow ranging from 0.5 to 0.8 m/s was detected in the aortic arch by directing the cannula tip toward the aortic arch, whereas flow velocity in the aortic arch was decreased to less than 0.2 m/s by directing the cannula tip toward the aortic root. Directing the aortic cannula tip toward the aortic root allowed the high-velocity exit flow to attenuate in velocity, so that flow velocity in the aortic arch was sufficiently reduced by reversed flow and vortex formation in both the normal and aortic arch aneurysm models.

Entities:  

Keywords:  Aortic cannula; Aortic root direction; Cardiopulmonary bypass; Dispersion cannula; Stealthflow cannula

Year:  2021        PMID: 33914206     DOI: 10.1007/s10047-021-01267-3

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  2 in total

1.  Assessment of perfusion toward the aortic valve using the new dispersion aortic cannula during coronary artery bypass surgery.

Authors:  R K Grooters; K C Thieman; R F Schneider; M G Nelson
Journal:  Tex Heart Inst J       Date:  2000

2.  Risk factors for perioperative ischemic stroke in cardiac surgery.

Authors:  Mário Augusto Cray da Costa; Maria Fernanda Gauer; Ricardo Zaneti Gomes; Marcelo Derbli Schafranski
Journal:  Rev Bras Cir Cardiovasc       Date:  2015 Jul-Sep