Literature DB >> 33914006

Light Transmittance and Depth of Cure of a Bulk Fill Composite Based on the Exposure Reciprocity Law.

Mateus Garcia Rocha1, Jean-François Roulet1, Mario Alexandre Coelho Sinhoreti2, Américo Bortolazzo Correr2, Dayane Oliveira1.   

Abstract

The objective of this study was to evaluate the effect of the exposure reciprocity law of a multi-wave light-emitting diode (LED) on the light transmittance (LT), depth of cure (DOC) and degree of conversion in-depth (DC) of a bulk fill composite. A bulk fill composite (EvoCeram® bulk fill, Ivoclar Vivadent) was photoactivated using the multi-wave LED (VALO™ Cordless, Ultradent). The LED was previously characterized using a spectrophotometer to standardize the time of exposure when using the Standard or Xtra-Power modes with the same radiant exposure of 20J/cm2. LT was evaluated through samples of the bulk fill composite every millimeter till 4 mm in-depth. DOC was evaluated according to the ISO 4049. DC of the central longitudinal cross-section from each sample of the DOC test was mapped using FT-NIR microscopy. Data were statistically analyzed according to the experimental design (α=0.05; ß=0.2). The radiant exposure in the violet wavelength range for Standard and Xtra-Power was 4.5 and 5.0 J/cm2, respectively; for the blue wavelength range the radiant exposure for Standard and Xtra-Power was 15.5 and 15.0 J/cm2, respectively. There was no statistical difference in the DOC using Standard or Xtra-Power light-curing modes, but the DOC was lower than the claimed by the manufacturer (4 mm). The DC was not significantly affected by the light-curing mode up to 4 mm in depth (p>0.05). According to exposure reciprocity law, the reduction in exposure time using the same radiant exposure did not affect the depth of cure of the bulk fill composite.

Entities:  

Mesh:

Substances:

Year:  2021        PMID: 33914006     DOI: 10.1590/0103-6440202103842

Source DB:  PubMed          Journal:  Braz Dent J        ISSN: 0103-6440


  3 in total

1.  Effect of dental headlights spectrum on the polymerization and working time of light-cured resin composites.

Authors:  Mateus-Garcia Rocha; Marc-Edward Ottenga; Panagiotis Zoidis; Stefany Pontes; Andre-Figueiredo Reis; Dayane Oliveira
Journal:  J Clin Exp Dent       Date:  2022-06-01

2.  Depth of Cure, Hardness, Roughness and Filler Dimension of Bulk-Fill Flowable, Conventional Flowable and High-Strength Universal Injectable Composites: An In Vitro Study.

Authors:  Francesco Saverio Ludovichetti; Patrizia Lucchi; Giulia Zambon; Luca Pezzato; Rachele Bertolini; Nicoletta Zerman; Edoardo Stellini; Sergio Mazzoleni
Journal:  Nanomaterials (Basel)       Date:  2022-06-07       Impact factor: 5.719

Review 3.  High-Power LED Units Currently Available for Dental Resin-Based Materials-A Review.

Authors:  Rita Almeida; Patricia Manarte-Monteiro; Joana Domingues; Carlos Falcão; Mariano Herrero-Climent; Blanca Ríos-Carrasco; Bernardo Ferreira Lemos
Journal:  Polymers (Basel)       Date:  2021-06-30       Impact factor: 4.329

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.