| Literature DB >> 33913277 |
Hee Jung Shin1, Su Hyun Lee2, Vivian Youngjean Park3, Jung Hyun Yoon3, Bong Joo Kang4, Bo La Yun5, Tae Hee Kim6, Eun Sook Ko7, Boo Kyung Han7, A Jung Chu8, Seo Young Park9, Hak Hee Kim1, Woo Kyung Moon10.
Abstract
PURPOSE: Interest in unenhanced magnetic resonance imaging (MRI) screening for breast cancer is growing due to concerns about gadolinium deposition in the brain and the high cost of contrast-enhanced MRI. The purpose of this report is to describe the protocol of the Diffusion-Weighted Magnetic Resonance Imaging Screening Trial (DWIST), which is a prospective, multicenter, intraindividual comparative cohort study designed to compare the performance of mammography, ultrasonography, dynamic contrast-enhanced (DCE) MRI, and diffusion-weighted (DW) MRI screening in women at high risk of developing breast cancer.Entities:
Keywords: Breast neoplasms; Clinical trial; Magnetic resonance imaging; Screening
Year: 2021 PMID: 33913277 PMCID: PMC8090809 DOI: 10.4048/jbc.2021.24.e19
Source DB: PubMed Journal: J Breast Cancer ISSN: 1738-6756 Impact factor: 3.588
Figure 1Study flow chart.
DCE = dynamic contrast-enhanced; MRI = magnetic resonance imaging; DW = diffusion-weighted.
DCE and DW MRI protocols of the DWIST
| Parameter | DCE MRI | DW MRI | |
|---|---|---|---|
| Equipment | |||
| Magnet field strength | 3.0 T | ||
| Type of coil | Double-breast, 16- or 18-channels | ||
| Acquisition parameter | |||
| Orientation | Axial | Axial | |
| In-plane resolution | ≤ 1 × 1 mm2 | ≤ 1.3 × 1.3 mm2 | |
| Slice thickness | ≤ 1 mm | ≤ 3 mm | |
| Imaging sequences | T2, preT1, T1 DCE, delayed T1 | EPI with b values of 0, 800, 1,200 sec/mm2 | |
| Post-processing | |||
| Subtraction | Postcontrast series minus precontrast series | NA | |
| ADC map | NA | 0 and 800 sec/mm2 | |
| MIP | Axial and sagittal | Axial and sagittal | |
| Acquisition time | 15–20 minutes | 6–7 minutes | |
DCE = dynamic contrast-enhanced; DW = diffusion-weighted; MRI = magnetic resonance imaging; DWIST = Diffusion-Weighted Magnetic Resonance Imaging Screening Trial; EPI = echo-planar imaging; NA = not applicable; ADC = apparent diffusion coefficient; MIP = maximum intensity projection.
Figure 2DW MRI interpretation guideline.
Note: ADC map is calculated from b = 0 and 800 sec/mm2 DW image, and the unit for the ADC value is (× 10−3 mm2/sec). An ADC cutoff of 1.3 was determined based on a diffusion level lexicon from EUSOBI guidelines [29] in order to decrease false positive and increase cancer detection.
DW = diffusion-weighted; MRI = magnetic resonance imaging; ADC = apparent diffusion coefficient; MIP = maximum-intensity projection; FU = follow-up; SI = signal intensity.
*These algorithms are not meant to dictate individual case management decisions. The ultimate decision regarding DW-MR interpretation must be made by the interpreting radiologist, taking into consideration all of the circumstances presented in an individual examination. Reprinted, with permission from [30].