Literature DB >> 33907884

Ultra-thin DSAEK using an innovative artificial anterior chamber pressuriser: a proof-of-concept study.

Alessandro Ruzza1, Mohit Parekh2,3, Luca Avoni4, Gabriela Wojcik2, Stefano Ferrari2, Ludovic Desneux5, Diego Ponzin2, Hannah J Levis6, Vito Romano6,7,8.   

Abstract

PURPOSE: To report the impact of establishing and maintaining a high intracameral pressure (ICP) of 200 mmHg on UT-DSAEK graft preparation using an artificial anterior chamber pressuriser (ACP) control unit (Moria SA, Antony, France).
METHOD: Retrospective laboratory and clinical study. Four paired donor corneas were mounted on an artificial anterior chamber and subjected to 70 mmHg ("low") and 200 mmHg ("high") ICP using an ACP system. The central corneal thinning rate was measured after 5 min using AS-OCT and the endothelial cell viability was analysed using trypan blue and live/dead staining following 70 mmHg and 200 mmHg ICP. Visual outcomes and complications in a clinical case series of nine patients with bullous keratopathy who underwent UT-DSAEK using 200 mmHg ICP during graft preparation are reported.
RESULTS: Laboratory outcomes showed 2 ± 1% and 2 ± 2% dead cells following 70 mmHg and 200 mmHg ICP respectively. Percentage viability in the 70 mmHg group (52.94 ± 5.88%) was not found to be significantly different (p = 0.7) compared to the 200 mmHg group (59.14 ± 10.43%). The mean corneal thinning rate after applying 200 mmHg ICP was 27 ± 13 μm/min centrally (7.2%/min). In the clinical case series, two cases were combined with cataract surgery. Re-bubbling rate was 11%. At the last follow-up (259 ± 109 days), graft thickness was 83 ± 22 μm centrally, endothelial cell density was 1175 ± 566 cell/mm2 and the BCVA of 0.08 ± 0.12 logMAR was recorded with no episodes of rejection.
CONCLUSION: ACP control unit for UT-DSAEK graft preparation helps in consistently obtaining UT-DSAEK grafts without compromising endothelial cell viability.
© 2021. The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.

Entities:  

Keywords:  Corneal thinning; Endothelial cells; Endothelial keratoplasty; Eye bank; Intracameral pressure; Thickness; Ultrathin DSAEK

Year:  2021        PMID: 33907884     DOI: 10.1007/s00417-021-05194-0

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  1 in total

Review 1.  Descemet's membrane endothelial keratoplasty (DMEK) versus Descemet's stripping automated endothelial keratoplasty (DSAEK) for corneal endothelial failure.

Authors:  Alastair J Stuart; Vito Romano; Gianni Virgili; Alex J Shortt
Journal:  Cochrane Database Syst Rev       Date:  2018-06-25
  1 in total
  1 in total

Review 1.  Role of AS-OCT in Managing Corneal Disorders.

Authors:  Nidhi Gupta; Akhil Varshney; Muralidhar Ramappa; Sayan Basu; Vito Romano; Manisha Acharya; Abha Gaur; Neha Kapur; Aastha Singh; Gaurav Shah; Isha Chaudhary; Nikunj Patel; Anil Tiwari; Anahita Kate; Virender Sangwan; Umang Mathur
Journal:  Diagnostics (Basel)       Date:  2022-04-07
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.