Literature DB >> 33901994

Intraoperative transimpedance and spread of excitation profile correlations with a lateral-wall cochlear implant electrode array.

Samuel Söderqvist1, Satu Lamminmäki2, Antti Aarnisalo2, Timo Hirvonen2, Saku T Sinkkonen2, Ville Sivonen2.   

Abstract

A limiting factor of cochlear implant technology is the spread of electrode-generated intracochlear electrical field (EF) leading to spread of neural excitation (SOE). In this study, we investigated the relation of the spread of the intracochlear EF, assessed via transimpedance matrix (TIM), and SOE. A total of 43 consecutive patients (ages 0.7-82 years; 31.0 ± 25.7 years, mean ± SD) implanted with a Cochlear Nucleus CI522 or CI622 cochlear implant with Slim Straight electrode array (altogether 51 ears) were included in the study. Cochlear nerve was visualized for all patients in preoperative imaging and there were no cochlear anomalies in the study sample. The stimulated electrodes were in the basal, middle, and apical parts of the electrode array (electrode numbers 6, 11, and 19, respectively). The stimulation level was 210 CL on average for the TIM measurement and always 230 CL for the SOE measurement. Approximately 90% of the individual TIM and SOE profiles correlated with each other (p < .05; r = 0.61-0.99). Also, the widths of the TIM and SOE peaks, computed at 50% of the maximum height, exhibited a weak correlation (r = 0.39, p = .007). The 50% widths of TIM and SOE were the same only in the apical part of the electrode array; in the basal part SOE was wider than TIM, and in the middle part TIM was wider than SOE (p < .01 and p = .048, respectively). Within each measurement, TIM 50% widths were different between all three parts of the electrode array, while for SOE, only the basal electrode differed from the middle electrode. Finally, the size of the cochlea and the 50% widths of TIM and SOE had the strongest correlation in the middle part of the electrode array (r = -0.63, and -0.37, respectively). Our results suggest that there is a correlation between the spread of intracochlear EF and neural SOE at least in the apical part of the electrode array used in this study, and that larger cochleae are associated with more focused TIM and SOE.
Copyright © 2021. Published by Elsevier B.V.

Entities:  

Keywords:  Channel interaction; Cochlear diameter; Cochlear implant; Intracochlear electrical field; Spread of excitation; Transimpedance matrix

Mesh:

Year:  2021        PMID: 33901994     DOI: 10.1016/j.heares.2021.108235

Source DB:  PubMed          Journal:  Hear Res        ISSN: 0378-5955            Impact factor:   3.208


  3 in total

Review 1.  Conversations in Cochlear Implantation: The Inner Ear Therapy of Today.

Authors:  Grant Rauterkus; Anne K Maxwell; Jacob B Kahane; Jennifer J Lentz; Moises A Arriaga
Journal:  Biomolecules       Date:  2022-04-29

Review 2.  Recent Advances in Cochlear Implant Electrode Array Design Parameters.

Authors:  Yavuz Nuri Ertas; Derya Ozpolat; Saime Nur Karasu; Nureddin Ashammakhi
Journal:  Micromachines (Basel)       Date:  2022-07-08       Impact factor: 3.523

3.  Intra-Cochlear Current Spread Correlates with Speech Perception in Experienced Adult Cochlear Implant Users.

Authors:  Charles-Alexandre Joly; Pierre Reynard; Ruben Hermann; Fabien Seldran; Stéphane Gallego; Samar Idriss; Hung Thai-Van
Journal:  J Clin Med       Date:  2021-12-13       Impact factor: 4.241

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.