Literature DB >> 33901938

Variable stiffness foot design and validation.

Christophe Lecomte1, Anna Lára Ármannsdóttir2, Felix Starker3, Heimir Tryggvason4, Kristin Briem5, Sigurður Brynjolfsson4.   

Abstract

Energy storing and returning prosthetic feet are commonly prescribed. Research has demonstrated advantages to use these types of prosthetic feet. However, their stiffness in the sagittal plane is fixed and cannot adapt to different walking tasks and user preference. In this paper, we propose a novel prosthetic foot design capable of modulating its stiffness in the sagittal plane. The Variable Stiffness Ankle unit (VSA) is mounted on a commercially available prosthetic foot. The stiffness of the foot is adjusted with a lightweight servo motor controlled wirelessly. The stiffness change is accomplished by moving the supports points on the glass fiber leaf spring of the VSA ankle unit. We described the design and characterized changes in ankle stiffness using a mechanical test bench. A novel method was used to capture mechanical test data using a six degree of freedom load cell, allowing us to contrast mechanical and biomechanical data. A transtibial unilateral amputee performed level ground walking on an instrumented treadmill. The VSA prosthetic foot exhibited ankle stiffness change in the mechanical test bench. Ankle stiffness changes were also confirmed during the biomechanical analysis. Future work will involve additional subjects. The VSA prosthetic foot could improve user satisfaction and help prosthetist to fine tune prosthetic feet during fittings.
Copyright © 2021 Elsevier Ltd. All rights reserved.

Keywords:  Biomechanics; Prosthetic design; Prosthetic foot; Trans-tibial amputee; Variable stiffness

Year:  2021        PMID: 33901938     DOI: 10.1016/j.jbiomech.2021.110440

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  2 in total

1.  Control Framework for Sloped Walking With a Powered Transfemoral Prosthesis.

Authors:  Namita Anil Kumar; Shawanee Patrick; Woolim Hong; Pilwon Hur
Journal:  Front Neurorobot       Date:  2022-01-11       Impact factor: 2.650

2.  Adapting Semi-Active Prostheses to Real-World Movements: Sensing and Controlling the Dynamic Mean Ankle Moment Arm with a Variable-Stiffness Foot on Ramps and Stairs.

Authors:  Jennifer K Leestma; Katherine Heidi Fehr; Peter G Adamczyk
Journal:  Sensors (Basel)       Date:  2021-09-08       Impact factor: 3.576

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.