| Literature DB >> 33900178 |
Susan L Hills, Andrea Morrison, Shawna Stuck, Kayleigh Sandhu, Krystal L Mason, Danielle Stanek, Julie Gabel, Matthew A Osborne, Betsy A Schroeder, Edhelene Rico, Cherie L Drenzek, Glen R Gallagher, Jennifer Fiddner, Lea A Heberlein-Larson, Catherine M Brown, Marc Fischer.
Abstract
Zika virus diagnostic testing and laboratory research increased considerably when Zika virus began spreading through the Americas in 2015, increasing the risk for potential Zika virus exposure of laboratory workers and biomedical researchers. We report 4 cases of laboratory-associated Zika virus disease in the United States during 2016-2019. Of these, 2 were associated with needlestick injuries; for the other 2 cases, the route of transmission was undetermined. In laboratories in which work with Zika virus is performed, good laboratory biosafety practices must be implemented and practiced to reduce the risk for infection among laboratory personnel.Entities:
Keywords: Zika virus; flavivirus; laboratory; mosquito-borne diseases; needlestick; occupational; vector-borne diseases; viruses; zoonoses
Mesh:
Year: 2021 PMID: 33900178 PMCID: PMC8084508 DOI: 10.3201/eid2705.203602
Source DB: PubMed Journal: Emerg Infect Dis ISSN: 1080-6040 Impact factor: 6.883
Laboratory results from 4 patients with laboratory-associated Zika virus disease, United States, 2016–2019*
| Days post-onset of collection† | Sample type | Test conducted‡ | Result | |
|---|---|---|---|---|
| Case 1 | 1 | Serum | RT-PCR | Zika virus RNA detected |
| 2 | Serum | RT-PCR | Zika virus RNA detected | |
| 2 | Urine | RT-PCR | Zika virus RNA detected | |
| 2 | Serum | IgM ELISA | Zika virus IgM equivocal | |
|
| 2 | Serum | PRNT | Zika virus titer >20, DENV titer <10 |
| Case 2 | 4 | Serum | RT-PCR | Negative |
| 4 | Urine | RT-PCR | Zika virus RNA detected | |
| 4 | Serum | IgM ELISA | Zika virus IgM positive | |
| 4 | Serum | PRNT | Zika virus titer <10, DENV titer <10 | |
| 20 | Serum | RT-PCR | Negative | |
| 20 | Urine | RT-PCR | Negative | |
| 20 | Serum | IgM ELISA | Zika virus IgM positive | |
|
| 20 | Serum | PRNT | Zika virus titer 320, DENV titer 20 |
| Case 3 | 2 | Serum | RT-PCR | Zika virus RNA detected |
| 2 | Serum | IgM ELISA | Negative | |
| 20 | Serum | RT-PCR | Negative | |
| 20 | Serum | IgM ELISA | Zika virus IgM positive | |
| 20 | Serum | PRNT | Zika virus titer >1280, DENV titer <10 | |
|
| ≈120 | Semen | RT-PCR | Zika virus RNA detected |
| Case 4 | 5 | Serum | RT-PCR | Negative |
| 5 | Urine | RT-PCR | Zika virus RNA detected | |
| 5 | Serum | PRNT | Zika virus titer 160 | |
| 10 | Urine | RT-PCR | Zika virus RNA detected | |
| 10 | Serum | RT-PCR | Negative | |
| 10 | Serum | IgM ELISA | Zika virus IgM positive | |
| 10 | Serum | PRNT | Zika virus titer 1280 |
*CDC, Centers for Disease Control and Prevention; DENV, dengue virus; PRNT, 90% plaque-reduction neutralization test; RT-PCR, reverse transcription PCR. †Day 0 equals day of illness onset. ‡Tests conducted at state public health laboratories, commercial laboratories, and CDC Arboviral Diseases Branch Reference Laboratory.