| Literature DB >> 33884150 |
Tanja Oud1, Yvette Kerkum2, Peter de Groot2, Harm Gijsbers1, Frans Nollet1, Merel-Anne Brehm1.
Abstract
OBJECTIVE: Hand orthoses are often prescribed for persons with chronic hand and wrist impairments. This study assessed the feasibility, in terms of production time and user satisfaction, of 3-dimensional printed hand orthoses compared with conventional hand orthoses for this population.Entities:
Keywords: feasibility; hand; orthotic device; printing; production time; satisfaction; three-dimensional
Year: 2021 PMID: 33884150 PMCID: PMC8054741 DOI: 10.2340/20030711-1000048
Source DB: PubMed Journal: J Rehabil Med Clin Commun ISSN: 2003-0711
Fig. 1Production process of a conventional orthosis. (A) Casting the hand and forearm, (B) adding resin and vacuuming, and (C) the final orthosis.
Fig. 2Production process of the 3-dimensional (3D)-printed orthosis. (A) Scanning the hand and forearm, (B) designing the orthosis based on the digital model of the hand, and (C) the 3D-printed orthosis.
Demographic and clinical characteristics of the participants
| No. | Sex (M/F), age (years) | Diagnosis | Reason for orthosis | Purpose of orthosis | Design of orthosis | Material of conventional orthosis |
|---|---|---|---|---|---|---|
| 1 | F: 28 | Joint hypermobility | Instability | Stabilization | Anti-hyperextension MCP 4-5 orthosis | Silver |
| 2 | F: 62 | Traumatic wrist injury with post-surgery complications | Pain | Immobilization | Circumferential wrist orthosis | Silicone |
| 3 | M: 19 | Joint hypermobility | Pain | Stabilization | Anti-swan neck IP 1 orthosis | Silver |
| 4 | F: 62 | STT-osteoarthritis | Pain | Immobilization | Circumferential wrist/thumb orthosis | Polypropylene |
| 5 | F: 51 | Traumatic wrist injury | Pain | Immobilization | Circumferential wrist orthosis | Resin |
| 6 | F: 54 | Stroke | Deformity | Correction | MCP anti-ulnar deviation orthosis | Silver |
| 7 | F: 79 | Mal-union distal radius | Pain | Immobilization | Dorsal wrist cock-up orthosis | Resin |
| 8 | F: 65 | Rheumatoid arthritis | Pain | Immobilization | Circumferential wrist orthosis | Leather |
| 9 | F: 52 | Partial wrist arthrodesis | Pain | Immobilization | Circumferential wrist orthosis | Leather |
| 10 | F: 49 | Charcot-Marie-Tooth disease | Muscle weakness | Support of function | Circumferential thumb orthosis | Silicone |
F: female; M: male; STT: scaphotrapeziotrapezoidal; MCP: metacarpophalangeal; IP: interphalangeal.
Satisfaction scores for the conventional orthosis and 3-dimensional (3D)-printed orthosis
| Satisfaction items | Conventional orthosis | 3D-printed orthosis | ||
|---|---|---|---|---|
| Median [IQR] | Median [IQR] | |||
| Comfort | ||||
| Casting: scanning | 4.0 [2.0] | 5.0 [0.0] | -2.121 | 0.034 |
| Fit | 4.0 [1.5] | 3.0 [2.3] | -0.660 | 0.509 |
| Material | 4.0 [1.3] | 3.5 [2.3] | -0.787 | 0.431 |
| Transpiration | 3.5 [2.5] | 4.0 [0.5] | -0.284 | 0.776 |
| Usability | ||||
| Effectiveness | 3.0 [2.0] | 4.0 [2.0] | -0.921 | 0.357 |
| Donning/doffing | 5.0 [0.3] | 5.0 [1.0] | 0.000 | 1.000 |
| Using closure | 5.0 [1.0] | 5.0 [2.0] | -0.414 | 0.679 |
| Aesthetics | ||||
| Cleaning | 4.5 [1.3] | 5.0 [1.0] | -1.289 | 0.197 |
| Appearance | 5.0 [2.0] | 4.0 [1.3] | -0.173 | 0.862 |
| Reactions of other people | 4.0 [1.3] | 4.0 [2.0] | -0.649 | 0.516 |
p < 0.05.