Gingival Thickness Assessment at Mandibular Incisors of Orthodontic Patients with Ultrasound and Cone-beam CT. A Cross-sectional Study.

Dimitrios Kloukos, Lydia Kakali, George Koukos, Anton Sculean, Andreas Stavropoulos, Christos Katsaros.   

Abstract

PURPOSE: To use and evaluate two methods for measuring gingival thickness (GT) at mandibular incisors of orthodontic patients and compare their performance in assessing periodontal anatomy through soft tissue thickness.
MATERIALS AND METHODS: The sample consisted of 40 consecutive adult orthodontic patients. GT was measured just before bracket placement at both central mandibular incisors, mid-facially on the buccal aspect, 2 mm apically to the free gingival margin with two methods: clinically with an ultrasound device (USD) and radiographically with cone-beam computed tomography (CBCT).
RESULTS: CBCT measurements were consistently higher than USD measurements, with the difference ranging from 0.13 mm to 0.21 mm. No statistically significant difference was noted between the repeated CBCT measurements at the right central incisor (bias = 0.05 mm; 95% CI = -0.01, 0.11; p = 0.104). Although the respective results for the left incisor statistically indicated that the measurements were not exactly replicated, the magnitude of the point estimate was small and not clinically significant (bias = 0.06 mm; 95% CI = 0.01, 0.11; p = 0.014). Small differences between CBCT measurements made by the 2 examiners at the left central incisor (bias = 0.06 mm; 95% CI = 0.01, 0.11; p = 0.014) were detected. However, this difference was minor and also not clinically significant. The respective analysis on the right incisor showed no statistically significant difference (bias = 0.05 mm; 95% CI = -0.01, 0.11; p = 0.246).
CONCLUSIONS: Based on reproducibility, CBCT imaging for gingival thickness assessment proved to be as reliable as ultrasound determination. However, CBCT consistently yielded higher values, albeit at a marginal level, than did the ultrasound device.

Entities:  

Keywords:  cone-beam CT; gingival phenotype; periodontal tissue; ultrasound

Year:  2021        PMID: 33881289     DOI: 10.3290/j.ohpd.b1248965

Source DB:  PubMed          Journal:  Oral Health Prev Dent        ISSN: 1602-1622            Impact factor:   1.256


  2 in total

1.  Digital evaluation of facial peri-implant mucosal thickness and its impact on dental implant aesthetics.

Authors:  Amr Khorshed; Javi Vilarrasa; Alberto Monje; Jose Nart; Gonzalo Blasi
Journal:  Clin Oral Investig       Date:  2022-10-19       Impact factor: 3.606

2.  Comparison of the Effectiveness of the Ultrasonic Method and Cone-Beam Computed Tomography Combined with Intraoral Scanning and Prosthetic-Driven Implant Planning Method in Determining the Gingival Phenotype in the Healthy Periodontium.

Authors:  Magdalena Bednarz-Tumidajewicz; Aneta Furtak; Aneta Zakrzewska; Małgorzata Rąpała; Karolina Gerreth; Tomasz Gedrange; Wojciech Bednarz
Journal:  Int J Environ Res Public Health       Date:  2022-09-27       Impact factor: 4.614

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.