Literature DB >> 33880949

In Response to the Letter to the Editor on Minimizing Adverse Skin Reactions to Wearable Continuous Glucose Monitoring Sensors.

Martin Mowitz1, Josefin Ulriksdotter1,2, Magnus Bruze1, Cecilia Svedman1.   

Abstract

Entities:  

Keywords:  allergic contact dermatitis; contact allergy; continuous glucose monitoring system; insulin pump; isobornyl acrylate; medical device

Mesh:

Substances:

Year:  2021        PMID: 33880949      PMCID: PMC8258509          DOI: 10.1177/19322968211008241

Source DB:  PubMed          Journal:  J Diabetes Sci Technol        ISSN: 1932-2968


× No keyword cloud information.
  6 in total

1.  Patch testing and diagnosis when suspecting allergic contact dermatitis from medical devices.

Authors:  Josefin Ulriksdotter; Martin Mowitz; Cecilia Svedman; Magnus Bruze
Journal:  Contact Dermatitis       Date:  2020-07-27       Impact factor: 6.600

Review 2.  Allergic contact dermatitis caused by medical devices for diabetes patients: A review.

Authors:  Anne Herman; Laurence de Montjoye; Isabelle Tromme; An Goossens; Marie Baeck
Journal:  Contact Dermatitis       Date:  2018-09-28       Impact factor: 6.600

3.  Allergic contact dermatitis caused by isobornyl acrylate in Freestyle® Libre, a newly introduced glucose sensor.

Authors:  Anne Herman; Olivier Aerts; Marie Baeck; Magnus Bruze; Christophe De Block; An Goossens; Nils Hamnerius; Sara Huygens; Dominique Maiter; Dominique Tennstedt; Bernard Vandeleene; Martin Mowitz
Journal:  Contact Dermatitis       Date:  2017-08-14       Impact factor: 6.600

4.  Changes in adhesive ingredients in continuous glucose monitoring systems may induce new contact allergy pattern.

Authors:  Cecilia Svedman; Josefin Ulriksdotter; Tina Lejding; Magnus Bruze; Martin Mowitz
Journal:  Contact Dermatitis       Date:  2021-01-09       Impact factor: 6.600

5.  Continuous glucose monitoring systems give contact dermatitis in children and adults despite efforts of providing less 'allergy- prone' devices: investigation and advice hampered by insufficient material for optimized patch test investigations.

Authors:  C Svedman; M Bruze; A Antelmi; N Hamnerius; I Hauksson; J Ulriksdotter; M Mowitz
Journal:  J Eur Acad Dermatol Venereol       Date:  2021-03       Impact factor: 6.166

6.  Minimizing Adverse Skin Reactions to Wearable Continuous Glucose Monitoring Sensors in Patients With Diabetes.

Authors:  Alexander Seibold
Journal:  J Diabetes Sci Technol       Date:  2021-01-08
  6 in total