Pregnancy in patients with prosthetic cardiac valve. A 10-year experience.

P Pavankumar1, P Venugopal, U Kaul, K S Iyer, B Das, A Sampathkumar, B Airon, I M Rao, M L Sharma, M L Bhatia.   

Abstract

Pregnancy after valve replacement has been considered hazardous because of maternal and fetal complications secondary to anticoagulant medication, in addition to basic myocardial problems. Of 229 females aged 15-45 years with prosthetic valve replacement, 37 (including 34 with Björk-Shiley valve and anticoagulants) subsequently had a total of 47 pregnancies. Fullterm delivery of a normal infant was achieved in 40 cases. There were three premature births, two spontaneous abortions, one stillbirth and one ectopic pregnancy. The fetal mortality was 8.5%. Valve thrombosis developed in two cases, but surgical treatment was successful. Oral anticoagulants (acenocoumarin and dipyridamole) were continued throughout pregnancy. Heparin was substituted before labour began, but discontinued after delivery, when effective oral anticoagulation was resumed. Our experience showed that pregnancy in women with mechanical heart valve prosthesis and continued oral intake of anticoagulants is safe and successful in most cases.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3387945     DOI: 10.3109/14017438809106045

Source DB:  PubMed          Journal:  Scand J Thorac Cardiovasc Surg        ISSN: 0036-5580


  7 in total

1.  Outcome of pregnancy in women with mechanical valves.

Authors:  Z A Ashour; H A Shawky; M Hassan Hussein
Journal:  Tex Heart Inst J       Date:  2000

2.  VTE, thrombophilia, antithrombotic therapy, and pregnancy: Antithrombotic Therapy and Prevention of Thrombosis, 9th ed: American College of Chest Physicians Evidence-Based Clinical Practice Guidelines.

Authors:  Shannon M Bates; Ian A Greer; Saskia Middeldorp; David L Veenstra; Anne-Marie Prabulos; Per Olav Vandvik
Journal:  Chest       Date:  2012-02       Impact factor: 9.410

Review 3.  Anticoagulants in pregnancy.

Authors:  C M Oakley
Journal:  Br Heart J       Date:  1995-08

4.  Anticoagulation in pregnant women with mechanical heart valve prostheses.

Authors:  S S Meschengieser; C G Fondevila; M T Santarelli; M A Lazzari
Journal:  Heart       Date:  1999-07       Impact factor: 5.994

5.  Follow-up and management of valvular heart disease patients with prosthetic valve: a clinical practice guideline for Indian scenario.

Authors:  Devendra Saksena; Yugal K Mishra; S Muralidharan; Vivek Kanhere; Pankaj Srivastava; C P Srivastava
Journal:  Indian J Thorac Cardiovasc Surg       Date:  2019-01-28

6.  Outcome of pregnancy in women with valve prostheses.

Authors:  E Sbarouni; C M Oakley
Journal:  Br Heart J       Date:  1994-02

7.  Anticoagulation therapy in pregnant women with mechanical heart valve.

Authors:  Hakkı Zafer İşcan; Muhammet Onur Hanedan; Anıl Özen; Adem Diken; Veysel Başar; Ertekin Utku Ünal; Cemal Levent Birincioğlu
Journal:  Turk Gogus Kalp Damar Cerrahisi Derg       Date:  2018-01-09       Impact factor: 0.332

  7 in total