Literature DB >> 33871788

Limitations of ventricular pacing maneuvers to differentiate orthodromic reciprocating tachycardia from atrioventricular nodal reentry tachycardia.

Péter Kupó1, Cristina Ioana Tutuianu2, Genadi Kaninski2, Zoltán Gingl2, László Sághy2, Róbert Pap2.   

Abstract

PURPOSE: Various ventricular pacing maneuvers have been developed to differentiate orthodromic reciprocating tachycardia (ORT) from atrioventricular nodal reentry tachycardia (AVNRT). We aimed to evaluate the diagnostic value of ventricular pacing maneuvers in patients undergoing catheter ablation for AVNRT/ORT.
METHODS: Sixty patients with supraventricular tachycardia (SVT) undergoing invasive EP study were included (ORT: 31, typical AVNRT: 18, atypical AVNRT: 11). Ventricular overdrive pacing (VOP) and resetting by premature ventricular stimulation (PVS) during SVT were analyzed by 3 independent observers blinded to the ultimate diagnosis. We determined intraclass correlation coefficient (ICC) for interobserver agreement and the diagnostic accuracy of consensual results.
RESULTS: Although specificity of all parameters was high (96-100%) for ORT, semi-quantitative parameters of VOP (requiring the recognition of specific ECG patterns) had lower interobserver reliability (ICC: 0.32-0.66) and sensitivity (16.1-77.4%). In contrast, most quantitative measurements of VOP and PVS showed good reproducibility (ICC: 0.93-0.95) and sensitivity (74.2-89.3%), but post-pacing interval after VOP needed correction with AV nodal conduction slowing. False negative results for diagnosing ORT were more common with left free wall vs. right free wall or septal, and slowly vs. fast-conducting septal APs. False positivity was only seen with a bystander, concealed nodo-fascicular/nodo-ventricular (NF/NV) AP in a case of AVNRT.
CONCLUSIONS: No single maneuver is 100% sensitive for ORT. Semi-quantitative features have limited reproducibility and all parameters can be misleading in the case of rate-dependent delay during VOP/PVS, ORT circuits remote from the pacing site, or a bystander, concealed NF/NV AP.
© 2021. Springer Science+Business Media, LLC, part of Springer Nature.

Entities:  

Keywords:  Accessory pathway; Atrioventricular nodal reentrant tachycardia; Atrioventricular reentrant tachycardia; Paroxysmal supraventricular tachycardia; Ventricular pacing maneuvers

Mesh:

Year:  2021        PMID: 33871788     DOI: 10.1007/s10840-021-00993-1

Source DB:  PubMed          Journal:  J Interv Card Electrophysiol        ISSN: 1383-875X            Impact factor:   1.900


  1 in total

1.  Ventricular fusion during resetting and entrainment of orthodromic supraventricular tachycardia involving septal accessory pathways. Implications for the differential diagnosis with atrioventricular nodal reentry.

Authors:  J M Ormaetxe; J Almendral; A Arenal; J D Martínez-Alday; A Pastor; J P Villacastín; J L Delcán
Journal:  Circulation       Date:  1993-12       Impact factor: 29.690

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.