Literature DB >> 33862199

Effects of remote care of patients with poorly controlled type 1 diabetes included in an experimental telemonitoring programme.

M Gaudillère1, C Pollin-Javon1, S Brunot1, S Villar Fimbel1, C Thivolet2.   

Abstract

AIM: To assess, in a real-life setting, the effectiveness of telemonitoring adults with type 1 diabetes (T1D) using continuous glucose monitoring in a telemedicine experiment.
METHODS: Experimentation in Telemedicine for the Improvement of Healthcare Pathways (ETAPES), an experimental telehealth programme for five chronic diseases, is supported by the French national healthcare system to promote telemedical care. Using data from a single university hospital centre, 72 adults were studied, including 42 subjects (58%) receiving insulin pump therapy and 30 (42%) receiving multiple daily injections, with a median age of 35.5 years [28.0; 45.0] and poorly controlled type 1 diabetes (T1D) with a mean ± standard error of mean (SEM) HbA1c value of 8.69 ± 0.13%. The primary study outcome was the difference in HbA1c values between baseline and the end of a 6-month follow-up. Other end points of interest were mean blood glucose, glucose management indicator (GMI) level and % time in range (3.9-10 mmol/L) or below or above range.
RESULTS: At month 6, mean HbA1c levels were significantly reduced by -0.5% (P < 0.001) as were also mean blood glucose levels (P = 0.015), with a significant increase of 6.75 ± 1.36% of time in range at month 3 and of 4.98 ± 1.4% at month 6. Such improvements did not depend on age, gender or type of insulin therapy, but were inversely correlated to initial HbA1c values on multivariate analysis (P < 0.001).
CONCLUSION: Although the use of telehealth monitoring offers efficacy and safety in the metabolic control of patients with T1D, it does not fulfil all of these patients' clinical needs. As such, this new healthcare pathway cannot replace, but is a useful complement to, face-to-face in-person clinical visits.
Copyright © 2021 Elsevier Masson SAS. All rights reserved.

Entities:  

Keywords:  CGM; Telemonitoring; Type 1 diabetes

Mesh:

Substances:

Year:  2021        PMID: 33862199     DOI: 10.1016/j.diabet.2021.101251

Source DB:  PubMed          Journal:  Diabetes Metab        ISSN: 1262-3636            Impact factor:   6.041


  1 in total

1.  Hybrid closed Loop improved glucose control compared to sensor-augmented pumps in outpatients with type 1 diabetes in real-life conditions with telehealth monitoring.

Authors:  C Thivolet; M Gaudilliere; S Villar Fimbel; N Bendelac; B Mestre; N Protsenko; S Brunot; M Nicolino
Journal:  Acta Diabetol       Date:  2021-11-01       Impact factor: 4.087

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.