| Literature DB >> 33858461 |
Ayokunle O Olanrewaju1, Benjamin P Sullivan1, Ashley R Bardon2, Tiffany J Lo3, Tim R Cressey4,5,6, Jonathan D Posner1,7,8, Paul K Drain9,10,11.
Abstract
OBJECTIVE: Maintaining adequate drug adherence is crucial to ensure the HIV prevention benefits of pre-exposure prophylaxis (PrEP). We developed an enzymatic assay for rapidly measuring tenofovir-diphosphate (TFV-DP) concentrations-a metabolite that indicates long-term PrEP adherence.Entities:
Keywords: Adherence; Enzymatic assay; Pre-exposure prophylaxis; Tenofovir diphosphate
Mesh:
Substances:
Year: 2021 PMID: 33858461 PMCID: PMC8048217 DOI: 10.1186/s12985-021-01543-x
Source DB: PubMed Journal: Virol J ISSN: 1743-422X Impact factor: 5.913
Fig. 1Workflow for RESTRICT assay for measuring antiretroviral drug concentrations. Patient blood samples are diluted in water to lyse red blood cells, release intracellular tenofovir diphosphate, and minimize assay interference from blood matrix components. Next diluted blood is added to the RESTRICT assay master mix and incubated at 37 °C for 30 min to allow time for DNA synthesis reactions. Finally, PicoGreen dye is added to stop the reaction and provide fluorescence readout. Samples with low TFV-DP concentration are conducive to DNA synthesis and provide high fluorescence signals, meanwhile samples with high TFV-DP concentration lead to DNA chain synthesis and provide low fluorescence signals
Demographic characteristics and LC–MS/MS measurements of study participants
| PrEP (N = 7) | No PrEP (N = 11) | |
|---|---|---|
| Median age (IQR) | 50 (45 to 62) | 57 (52 to 65) |
| Body mass index, BMI (kg/m2) | 25 (23 to 27) | 31 (23 to 37) |
| Number of women (%) | 1 (14%) | 3 (27%) |
| LC–MS TFV-DP concentration (fmol/punch) | 717, 2248, 2453, 2556, 675, 559, undetectable | All undetectable |
Fig. 2Comparison between RESTRICT assay and LC–MS/MS TFV-DP measurements. a A priori fluorescence thresholds corresponding to adequate adherence (700 fmol/punch) and perfect adherence (1250 fmol/punch) among men who have sex with men receiving PrEP were interpolated from a standard curve obtained with TFV-DP spiked in blood. b Using the a priori cut-off of 87.2, RESTRICT distinguished samples with TFV-DP concentrations ≥ 700 fmol/punch with 100% sensitivity and 92.9% specificity. c Using the a priori fluorescence threshold of 71.0 corresponding to ≥ 1250 fmol/punch yielded 100% sensitivity and specificity in distinguishing samples with TFV-DP corresponding to perfect adherence. d RESTRICT fluorescence intensities were correlated with LC–MS/MS TFV-DP concentrations. Pearson correlation coefficient r = − 0.845 (CI − 0.941 to − 0.624), p < 0.0001