Thirty-Day Results of the Novel CGuard-Covered Stent in Patients Undergoing Carotid Artery Stenting.

Konstantinos Tigkiropoulos1, Ioakeim Papoutsis1, Manolis Abatzis-Papadopoulos1, Panagiotis Kousidis1, Dimitrios Mpismpos1, Nikolaos Melas1, Kyriakos Stavridis1, Dimitrios Karamanos1, Ioannis Lazaridis1, Nikolaos Saratzis1.   

Abstract

OBJECTIVE: The aim of this study was to provide early-term evaluation, safety, and efficacy of the novel CGuard (Inspire MD, Tel Aviv, Israel) micromesh self-expanding stent with embolic protection system (EPS) during carotid artery stenting (CAS) procedure.
MATERIALS AND METHODS: All patients who underwent CAS with CGuard carotid stent system from January 2018 to September 2020 in a tertiary center were prospectively evaluated. Primary endpoints included technical success and perioperative neurological events (0-48 hours). Secondary endpoint was the rate of neurologic, cardiac events, and death (major adverse event or MAE) at 30 days. Patency of CGuard, peak systolic velocity (PSV), and end diastolic velocity (EDV) were evaluated at 30 days with duplex ultrasound.
RESULTS: A total of 103 patients underwent CAS procedure. Forty patients were symptomatic, and 63 patients were asymptomatic with stenosis greater than 70%. Technical success was 100%. Local anesthesia was applied in 94 patients (93%). Embolic protection devices were used in 6 patients (5.8%). Access site complications were 1.9%. Mean internal carotid artery stenosis diameter reduced from 79.47% to 14.68%. Two patients had transient ischemic attack (1.9%) and 1 patient experienced a cerebral hyperperfusion syndrome (CHS) perioperatively. External carotid artery (ECA) occlusion occurred in 1.9%. Four patients experienced jaw claudication (3.8%) postoperatively. Mean time of operation was 41 minutes. Mean duration of hospitalization was 3.1 days. The 30-day rate of MAE was 0%. CGuard patency was 100%, mean internal carotid PSV was reduced from 251.57 to 77.29 cm/s, and mean internal carotid EDV was reduced from 154.62 to 24.63 cm/s at 30 days.
CONCLUSION: Our study shows that CGuard stent with EPS is an effective and safe device for treatment of carotid artery stenosis with acceptable low perioperative neurologic events, even with low embolic protection device usage. Larger multicenter and randomized studies are necessary to confirm its long-term efficacy.

Entities:  

Keywords:  carotid artery stenosis; carotid artery stenting; double mesh technology; mesh-covered stent; stroke

Mesh:

Year:  2021        PMID: 33855877     DOI: 10.1177/15266028211007466

Source DB:  PubMed          Journal:  J Endovasc Ther        ISSN: 1526-6028            Impact factor:   3.487


  2 in total

Review 1.  Clinical Outcomes of Second- versus First-Generation Carotid Stents: A Systematic Review and Meta-Analysis.

Authors:  Adam Mazurek; Krzysztof Malinowski; Kenneth Rosenfield; Laura Capoccia; Francesco Speziale; Gianmarco de Donato; Carlo Setacci; Christian Wissgott; Pasqualino Sirignano; Lukasz Tekieli; Andrey Karpenko; Waclaw Kuczmik; Eugenio Stabile; David Christopher Metzger; Max Amor; Adnan H Siddiqui; Antonio Micari; Piotr Pieniążek; Alberto Cremonesi; Joachim Schofer; Andrej Schmidt; Piotr Musialek
Journal:  J Clin Med       Date:  2022-08-17       Impact factor: 4.964

2.  Safety and Efficacy of Carotid Artery Stenting with the CGuard Double-layer Stent in Acute Ischemic Stroke.

Authors:  Tomas Klail; Christoph Kurmann; Johannes Kaesmacher; Adnan Mujanovic; Eike I Piechowiak; Tomas Dobrocky; Sara Pilgram-Pastor; Adrian Scutelnic; Mirjam R Heldner; Jan Gralla; Pasquale Mordasini
Journal:  Clin Neuroradiol       Date:  2022-09-07       Impact factor: 3.156

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.