Abstract

We assessed extracranial contamination of the near-infrared spectroscopy (NIRS) signal during administration of phenylephrine. The study was performed with NIRO 200NX which employs both the Modified Beer-Lambert (MBL) method to measure total hemoglobin (tHb, expressed in µM), and Spatially Resolved Spectroscopy (SRS) to measure total hemoglobin content (nTHI, expressed in arbitrary units (a.u.)). SRS tends to not be affected by extracranial blood flow. As vasoconstriction with phenylephrine mainly occurs in the extracranial area, we hypothesized that if NIRS measurements are indeed prone to extracranial contamination, tHb will be more affected by the administration of phenylephrine than nTHI. After ethical committee approval, 20 consenting cardiac surgery patients were included. Phenylephrine was administered whenever clinically indicated and its effect on nTHI and tHb was evaluated. To adjust for the difference in raw scale units, Z-scores were calculated. Data were analyzed with Wilcoxon Signed Ranks Test and the Hodges-Lehmann method. A total of 191 data sets were obtained in 20 patients (10 male, 65 ± 15 years, 77 ± 16 kg, 166 ± 11 cm). The median difference before and after administration of phenylephrine was - 0.006 a.u. [95%CI - 0.010 to - 0.002] (p < 0.001) and - 0.415 µM [95%CI - 0.665 to - 0.205] (p < 0.001) for nTHI and tHb, respectively. The median difference between the Z-scores of nTHI and tHb was - 0.02 [95%CI - 0.04 to - 0.003] (p = 0.03), with a higher variability in the Z-scores of tHb. Phenylephrine induced significant larger changes in MBL values compared to SRS values, indicating that the MBL method might be more prone to extracranial contamination. Trial and clinical registry: Trial registration number: B670201939459, ethical committee number: 2019/0265, date of approval: March 19, 2019.
© 2021. The Author(s), under exclusive licence to Springer Nature B.V.

Entities:  

Keywords:  Blood volume; Extracranial contamination; NIRS; Near-infrared spectroscopy; Phenylephrine

Mesh:

Substances:

Year:  2021        PMID: 33846886     DOI: 10.1007/s10877-021-00702-3

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   1.977


  1 in total

Review 1.  Near-infrared spectroscopy (NIRS) monitoring in contemporary anesthesia and critical care.

Authors:  A Moerman; P Wouters
Journal:  Acta Anaesthesiol Belg       Date:  2010
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.