Literature DB >> 3384619

Interactions of paramagnetic contrast agents and the spin echo pulse sequence.

P L Davis1, D L Parker, J A Nelson, J S Gillen, V M Runge.   

Abstract

The theoretical equations for paramagnetic contrast agent effects and the spin echo pulse sequence are combined to graph magnetic resonance (MR) intensity as a function of paramagnetic contrast agent concentration for various tissues. Analysis of the graphs and equations demonstrate several technical and clinical implications. These include: (1) positive enhancement is most likely to occur with short TEs and TRs; (2) changes in machine parameters TE and TR will change the concentration of agent at which the peak enhancing MR intensity will occur; (3) there is an absolute maximum MR intensity that can be reached with contrast enhancement; (4) the maximum MR intensity reached with enhancement is dependent on the tissues' T2 and, to a lesser degree, T1 relaxation times; (5) certain TE and TR combinations will cause no enhancement; (6) if positive enhancement does occur, it will usually occur only over a limited range of agent concentration; and (7) the tissues' T1 relaxation time but not its T2 time determines whether positive enhancement will occur and the relative amount of enhancement.

Mesh:

Substances:

Year:  1988        PMID: 3384619     DOI: 10.1097/00004424-198805000-00010

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  3 in total

1.  Comparison of the added value of contrast-enhanced 3D fluid-attenuated inversion recovery and magnetization-prepared rapid acquisition of gradient echo sequences in relation to conventional postcontrast T1-weighted images for the evaluation of leptomeningeal diseases at 3T.

Authors:  H Fukuoka; T Hirai; T Okuda; Y Shigematsu; A Sasao; E Kimura; T Hirano; S Yano; R Murakami; Y Yamashita
Journal:  AJNR Am J Neuroradiol       Date:  2009-12-24       Impact factor: 3.825

2.  The added value of double dose gadolinium enhanced 3D T2 fluid-attenuated inversion recovery for evaluating small brain metastases.

Authors:  Sung Jun Ahn; Tae-Sub Chung; Jong-Hee Chang; Seung-Koo Lee
Journal:  Yonsei Med J       Date:  2014-09       Impact factor: 2.759

3.  Utility of Contrast-Enhanced T2 FLAIR for Imaging Brain Metastases Using a Half-dose High-Relaxivity Contrast Agent.

Authors:  T Jin; M Ge; R Huang; Y Yang; T Liu; Q Zhan; Z Yao; H Zhang
Journal:  AJNR Am J Neuroradiol       Date:  2020-12-24       Impact factor: 3.825

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.