Nobuhiro Asai1, Daisuke Sakanashi2, Wataru Ohashi3, Akiko Nakamura2, Yuzuka Kawamoto4, Narimi Miyazaki4, Tomoko Ohno4, Atsuko Yamada4, Sumie Chida4, Yuichi Shibata4, Hideo Kato2, Arufumi Shiota4, Mao Hagihara5, Isao Koita4, Yuka Yamagishi2, Hiroyuki Suematsu4, Hirotoshi Ohta4, Hiroshige Mikamo6. 1. Department of Clinical Infectious Diseases, Aichi Medical University Hospital, Aichi, Japan; Department of Infection Control and Prevention, Aichi Medical University Hospital, Japan; Department of Pathology, University of Michigan, Ann Arbor, MI, USA. 2. Department of Clinical Infectious Diseases, Aichi Medical University Hospital, Aichi, Japan; Department of Infection Control and Prevention, Aichi Medical University Hospital, Japan. 3. Division of Biostatistics, Clinical Research Center, Aichi Medical University Hospital, Japan. 4. Department of Infection Control and Prevention, Aichi Medical University Hospital, Japan. 5. Department of Clinical Infectious Diseases, Aichi Medical University Hospital, Aichi, Japan; Department of Infection Control and Prevention, Aichi Medical University Hospital, Japan; Department of Molecular Epidemiology and Biomedical Sciences, Aichi Medical University, Aichi, Japan. 6. Department of Clinical Infectious Diseases, Aichi Medical University Hospital, Aichi, Japan; Department of Infection Control and Prevention, Aichi Medical University Hospital, Japan. Electronic address: mikamo@aichi-med-u.ac.jp.
Abstract
INTRODUCTION: The pandemic of a novel coronavirus disease 2019 (COVID-19) caused by a severe acute respiratory coronavirus 2 (SARS-CoV-2) infection has been problematic worldwide. A new SARS-CoV-2 antigen test (LUMIPULSEⓇ) was licensed and widely used in Japan since May 2020. We conducted this study intending to whether the automated quantitative CLEIA antigen test using a saliva sample is effective and valid for the diagnosis of COVID-19. PATIENTS AND METHODS: We analyzed and compared the diagnostic accuracy of both the automated quantitative CLEIA antigen test and real-time RT-PCR (rRT-PCR) using a saliva sample from individuals suspected as having COVID-19. RESULTS: A total of 305 samples were collected and tested in Aichi Medical University Hospital and affiliated facilities from December 2020 until January 2021 at our institute. Using reverse-transcription PCR as a reference, the AUROC of the automated quantitative CLEIA antigen test was 0.903 (95% confidential interval 0.845-0.962, p < 0.001). The appropriate cut-off antigen level was 4.0 pg/mL and had a sensitivity of 77.8%, a specificity of 99.6%, a positive predictive value of 98%, and a negative predictive value of 94.5%. On the other hand, the diagnostic accuracy of the antigen test decreased among patients among patients with COVID-19 with threshold cycle (Ct-value)≥27, which shows the AUROC was 0.795 (95%CI 0.687-0.907, p < 0.001). CONCLUSION: While the automated quantitative CLEIA antigen test from saliva specimen could be one of the most useful diagnostic tests for the diagnosis of COVID-19 in general practice, clinicians should know the limitations of the antigen test.
INTRODUCTION: The pandemic of a novel coronavirus disease 2019 (COVID-19) caused by a severe acute respiratory coronavirus 2 (SARS-CoV-2) infection has been problematic worldwide. A new SARS-CoV-2 antigen test (LUMIPULSEⓇ) was licensed and widely used in Japan since May 2020. We conducted this study intending to whether the automated quantitative CLEIA antigen test using a saliva sample is effective and valid for the diagnosis of COVID-19. PATIENTS AND METHODS: We analyzed and compared the diagnostic accuracy of both the automated quantitative CLEIA antigen test and real-time RT-PCR (rRT-PCR) using a saliva sample from individuals suspected as having COVID-19. RESULTS: A total of 305 samples were collected and tested in Aichi Medical University Hospital and affiliated facilities from December 2020 until January 2021 at our institute. Using reverse-transcription PCR as a reference, the AUROC of the automated quantitative CLEIA antigen test was 0.903 (95% confidential interval 0.845-0.962, p < 0.001). The appropriate cut-off antigen level was 4.0 pg/mL and had a sensitivity of 77.8%, a specificity of 99.6%, a positive predictive value of 98%, and a negative predictive value of 94.5%. On the other hand, the diagnostic accuracy of the antigen test decreased among patients among patients with COVID-19 with threshold cycle (Ct-value)≥27, which shows the AUROC was 0.795 (95%CI 0.687-0.907, p < 0.001). CONCLUSION: While the automated quantitative CLEIA antigen test from saliva specimen could be one of the most useful diagnostic tests for the diagnosis of COVID-19 in general practice, clinicians should know the limitations of the antigen test.
Emergence of a novel coronavirus in Wuhan, China, severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and the pandemic of COVID-19 (coronavirus disease 2019) caused a severe crisis in healthcare as well as the economy worldwide, and still are threatening at the time of January 2021 [[1], [2], [3]]. While the diagnosis as having COVID-19 has been made by reverse-transcription-polymerase chain reaction (RT-PCR), it is costly and requires a trained laboratory technician and medical equipment to perform, taking 3–4 h per assay [4]. A newly developed SARS-CoV-2 antigen test system, LUMIPULSE has been licensed since May 2020 in Japan [5], and has been used in general practice. We performed this retrospective study to report the efficacy and validity of automated quantitative chemiluminescence enzyme immunoassay (CLEIA) antigen test (LUMIPULSE antigen test) for the diagnosis of COVID-19. As far as we had searched, this is the first report documenting the diagnostic accuracy of the automated quantitative chemiluminescence enzyme immunoassay (CLEIA) antigen test by using saliva samples for the diagnosis of COVID-19.
Patients and methods
Patients and samples
We collected 305 saliva clinical specimens from individuals from Dec 2020 until Jan 2021 at Aichi Medical University Hospital and affiliated facilities. All patients were suspected to have COVID-19 based on their clinical symptoms (within 9 days from the onset) or met the definition of close contact with COVID-19patients. Saliva was collected based on the standard protocol in the same manner as the previous study [6]. Using the samples, we performed rRT-PCR as well as the automated quantitative CLEIA antigen test in diagnosing COVID-19patients. Then, we analyzed the diagnostic characteristics such as diagnostic accuracy and ROC curves, threshold cycle (Ct) value of the rRT-PCR, and compared the results of the two methods. This study was approved by the Institutional Review Board of Aichi Medical University Hospital.
SARS-CoV-2 antigen test
As for the SARS-CoV-2 antigen test, we used a newly developed SARS-CoV-2 antigen test system, LUMIPULSE SARS-CoV-2 antigen kit (Fujirebio, Japan), based on CLEIA, following the manufacture’s protocol. Based on the package insert, a cut-off value of 0.67 pg/mL was used. The performance of the automated quantitative CLEIA antigen test for the detection of SARS-CoV-2 antigen was evaluated by comparing the results with those from rRT-PCR experiment. Qualitative results (number of positive, negative, or invalid) and quantitative results (antigen quantities or threshold cycle value; used a smaller value from N1 and N2) were compared between the automated quantitative CLEIA antigen test and rRT-PCR.
rRT-PCR
rRT-PCR was performed by using BD MAX system (a fully-integrated, automated platform that performs nucleic acid extraction and real-time PCR) (Japan Becton Dickinson and Company, Japan). The re-suspended saliva was centrifuged at 500×g for 1 min, and the volumes of 750 μL supernatant fluid were assayed on the BD MAX system using the BD SARS-CoV-2 reagents for BD MAX System. In these reagents, the primer and double-quencher probe sets were based on the United States Centers for Disease Control and Prevention (US CDC) assay for specific detection of SARS-CoV-2 by amplifying two unique regions of the N gene (i.e., N1 and N2), and the human RNase P gene as an internal control.
Statistical analysis
Statistical analyses were performed using SPSS Version 26 for Windows (SPSS Inc., Chicago, IL, USA). P-values<0.05 were considered statistically significant.
Results
A total of 305 saliva samples were tested and the rRT-PCR results were 63 (20.7%) positive and 242 (79.3%) negative. The median antigen level of the positive rRT-PCR samples was 18.6 pg/ml (range 1.14–17046.6) and the median Ct-value was 26.6 cycles (range 15.5–36.2). We had 4 false-positive (positive-automated quantitative CLEIA antigen test, but negative-rRT-PCR) and 14 false-negative (negative-automated quantitative CLEIA antigen test, but positive-rRT-PCR). All samples of false-negative showed a Ct-value of 29.2–35.0 by rRT-PCR. False-positive samples revealed the antigen test ranging 0.75–3.66 pg/ml. Compared to the positive and negative results of rRT-PCR, the mean Ct-value was much lower in the positive samples than in the negative ones (24.9 v.s. 44.5 cycles, p < 0.001 by Mann-Whitney U test) (Fig. 1
). The mean antigen level of positive rRT-PCR samples was much higher than that of the negative rRT-PCR samples (652.9 v.s. 0.2 pg/ml, p < 0.001 by Mann-Whitney U test). Fig. 2
shows the correlation between the antigen levels and the Ct-values of the rRT-PCR (R2 = 0.9336).
Fig. 1
shows the comparison between qualitative results of antigen CLEIA and threshold cycle values of rRT-PCR.
Fig. 2
shows the correlation the antigen levels and the Ct-values of rRT-PCR relationship.
shows the comparison between qualitative results of antigen CLEIA and threshold cycle values of rRT-PCR.shows the correlation the antigen levels and the Ct-values of rRT-PCR relationship.
Diagnostic accuracy of the automated quantitative CLEIA antigen test by saliva sample
Using the result of rRT-PCR as a reference, the area under receiver-operating characteristic (AUROC) curve is 0.903 [p < 0.001, 95% confidential interval (CI) 0.845–0.962]. The cut-off is 0.67, which was recommended by Fujirebio, and had a sensitivity of 77.8%, a specificity of 98.3%, a positive predictive value of 77.8%, and a negative predictive value of 94.4%. The appropriate cut-off antigen level was 4.0 pg/mL and had a sensitivity of 77.8%, a specificity of 99.6%, a positive predictive value of 98%, and a negative predictive value of 94.5% as shown in Table 1
. The cut-off was set based on the Youden Index [7]. Regarding cases with Ct-value≥27, the AUROC of the antigen test was 0.797 (p < 0.001, 95%CI 0.687–0.907). The diagnostic accuracy decreased as shown in Table 1 and Fig. 1. The appropriate cut-off antigen level was 0.67 pg/mL and had a sensitivity of 53.3%, a specificity of 94.4%, a positive predictive value of 80%, and a negative predictive value of 98.3% as shown in Table 1.
Table 1
Diagnostic accuracy of LUMIPULSE for the diagnosis if COVID-19.
Diagnostic accuracy of LUMIPULSE for the diagnosis if COVID-19.COVID-19, coronavirus disease 2019; Ct, threshold cycle; PPV, positive predictive value; NPV, negative predictive value; YI, Youden index.
Discussion
We found that the automated quantitative CLEIA antigen test using a saliva sample was effective and valid for the diagnosis of COVID-19. Some already reported the effectiveness of the automated quantitative CLEIA antigen test for the diagnosis of COVID-19 using a nasopharyngeal sample [7,8]. Compared to the studies, the automated quantitative CLEIA antigen test using a saliva sample could be one of the most effective diagnostic tests, which is acceptable. This test does not require any specific instruments or trained technicians. The automated quantitative CLEIA antigen test is less expensive and faster to obtain the result than RT-PCR, so it could replace RT-PCR for the near future in a medical institute that has no equipment for PCR. The automated quantitative CLEIA antigen test is already used widely for the diagnosis of seasonal influenza virus infection and viral hepatitis [9]. In contrast to rRT-PCR which needs 3–4 h, the automated quantitative CLEIA antigen test needs just 30–45 min. The general cost of the antigen test is much cheaper, which is one-third (6000 JPY = 56USD) in comparison to rRT-PCR (18,000JPY = 168USD) [10]. Moreover, obtaining saliva samples is safer and easier than nasopharyngeal samples for the prevention of secondary transmission from patients to medical staff. On the other hand, the diagnostic accuracy of the automated quantitative CLEIA antigen test was lower in patients with Ct ≧ 27 cycles than those with Ct < 27 cycles. We had 4 false-positive cases, exhibiting values of 0.75–3.66 pg/ml by the automated quantitative CLEIA antigen test. As written in the package insert, the diagnosis should be made with clinical information among the patients with a value of 0.75–3.66 pg/ml from the saliva sample. While a recent study demonstrated that patients with Ct-value≧34 would not be extremely contagious [11], patients with a value of 27–34 could be a cause of secondary transmission to others. Clinicians should be aware of the limitations of the antigen test.We previously reported that 47% of COVID-19 pneumonia patients were asymptomatic, even when radiological findings on chest CT were confirmed [3]. The severity of COVID-19 could be correlated with the viral load as well as the Ct-value of RT-PCR [12,13]. Patients who show a high antigen level of the automated quantitative CLEIA antigen test should receive a chest CT scan, particularly those with underlying disease. Otherwise, pneumonia could be missed, resulting in an unexpected death.There are several limitations in our study. First, we tested only for SARS-CoV-2 from saliva samples and not for coinfection with any other viruses. Second, there was no clinical information of the patients. Therefore, we could not evaluate any correlation between clinical manifestations and Ct-value.In conclusion, the automated quantitative CLEIA antigen test of SARS-CoV-2 by saliva sample is effective for the diagnosis of COVID-19 in general practice and could replace r-RT-PCR. However, clinicians should know that the diagnostic accuracy among patients with Ct-value≧27 cycles could be lower than those with Ct-value<27 cycles.
Author contributions
DS, NA, AK, and HM designed this study. NA and DS drafted this manuscript. DS, AN, YK, NM, TO, AY, IK, HS performed the LUMIPULSE antigen test and rRT-PCR. NA, DS, WO, AN, HK, AS, YY and MH contributed to the data collection, data analysis. HM supervised, reviewed, and edited this manuscript.
Declaration of competing interest
H. Mikamo received grant support from , , , Sumitomo Dainippon Pharma Co., Ltd., and FUJIFILM Toyama Chemical Co., Ltd., payment for lectures from Astellas Pharma Inc., MSD K.K., Daiichi Sankyo Co., Ltd., Sumitomo Dainippon Pharma Co., Ltd., MIYARISAN Pharmaceutical Co., Ltd. Becton, Dickinson and Company Japan, and FUJIFILM Toyama Chemical Co. Ltd. The other authors declare that they have no conflicts of interest.
Authors: Anastasia Tapari; Georgia G Braliou; Maria Papaefthimiou; Helen Mavriki; Panagiota I Kontou; Georgios K Nikolopoulos; Pantelis G Bagos Journal: Diagnostics (Basel) Date: 2022-06-04
Authors: Andreas Osterman; Maximilian Iglhaut; Andreas Lehner; Patricia Späth; Marcel Stern; Hanna Autenrieth; Maximilian Muenchhoff; Alexander Graf; Stefan Krebs; Helmut Blum; Armin Baiker; Natascha Grzimek-Koschewa; Ulrike Protzer; Lars Kaderali; Hanna-Mari Baldauf; Oliver T Keppler Journal: Med Microbiol Immunol Date: 2021-08-20 Impact factor: 3.402
Authors: Brandon Bustos-Garcia; Sylvia Garza-Manero; Nallely Cano-Dominguez; Dulce Maria Lopez-Sanchez; Gonzalo Salgado-Montes de Oca; Alfonso Salgado-Aguayo; Felix Recillas-Targa; Santiago Avila-Rios; Victor Julian Valdes Journal: Vaccines (Basel) Date: 2022-05-06
Authors: Lukas E Brümmer; Stephan Katzenschlager; Mary Gaeddert; Christian Erdmann; Stephani Schmitz; Marc Bota; Maurizio Grilli; Jan Larmann; Markus A Weigand; Nira R Pollock; Aurélien Macé; Sergio Carmona; Stefano Ongarello; Jilian A Sacks; Claudia M Denkinger Journal: PLoS Med Date: 2021-08-12 Impact factor: 11.069