Rationing oxygen use during total intravenous anaesthesia: a proportionate response?

Morgan Back1, George Zhong2, Adam Al-Attar3, Rebecca Sutton3, Cliff Shelton4.   

Abstract

Entities:  

Keywords:  COVID-19; fresh gas flow; healthcare cost; sustainability; total intravenous anaesthesia

Mesh:

Substances:

Year:  2021        PMID: 33840451      PMCID: PMC9155276          DOI: 10.1016/j.bja.2021.02.031

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   11.719


× No keyword cloud information.
Editor—We read with interest Hall and Chakladar's comment on the recent study by Zhong and colleagues of the environmental and economic impacts of fresh gas flow (FGF) during total i.v. anaesthesia. Their concern about oxygen use during the COVID-19 pandemic sadly remains topical, as the disease continues to overwhelm critical care capacity in many hospitals. Hall and Chakladar suggest that higher FGF rates during the provision of non-inhalation general anaesthesia should be avoided until after the pandemic has abated, citing reports of hospitals that have experienced oxygen shortages. In the UK, which continues to be severely affected by COVID-19, there have been several cases of oxygen supply issues during surges of hospital admissions. However, this appears not to be as a result of a lack of oxygen per se, but the per minute oxygen demand exceeding the flow capacity of supply systems. Internationally, absolute shortages of oxygen have been experienced, for example in sub-Saharan Africa. This appears to be largely as a result of economic and infrastructure factors, but is not representative of a global oxygen shortage. Whilst low-flow anaesthesia should form part of a strategy to cope with exceptional surges in oxygen demand, its potential contribution to this endeavour is unfortunately minimal. The total consumption of oxygen per patient using higher FGFs via a circle system is not as great as it may at first appear when considered in context. Using Hall and Chakladar's example, a 6-h case using FGF of 6 L min−1 and a fraction of inspired oxygen (FiO2) of 0.3 requires 252 L of oxygen. Whilst this may appear to be a large volume, it represents only 0.7 L min−1 of oxygen gas usage; lower than the minimal requirements of even low-flow nasal cannulae. Furthermore, it has been shown that FiO2 may be significantly lower than the fraction of oxygen delivered at low FGFs because of both oxygen consumption and increased rebreathing of exhaled gases by the patient. While Hall and Chakladar suggest that providing an FiO2 of 0.3 at 1 L min−1 requires an oxygen flow of 0.1 L min−1, Hendrickx and colleagues found in their in vivo study that oxygen flows of 0.2 L min−1 were required to maintain a steady-state FiO2 of 0.31 within the circle system at a total FGF of 1 L min−1. It is likely that even higher oxygen flow rates would be required for patients with increased oxygen consumption at low FGFs. Consequently, oxygen savings are not proportional to the reduction in FGF for a given FiO2. During times of extraordinary oxygen demand we agree that clinicians may be required to take all available steps to safely minimise consumption. But even during the COVID-19 pandemic, increasing the FGF from 1 to 6 L min−1 during non-inhalation anaesthesia remains a reasonable option at most times, representing only a 0.5 L min−1 increase in oxygen gas usage when delivering an FiO2 of 0.3. In addition to its tragic impacts on the health and wellbeing of millions of people, the COVID-19 pandemic is responsible for profound adverse economic and environmental effects. , Measures that clinicians can take to mitigate these problems, including optimising FGF rates, are perhaps now more relevant than ever.

Declarations of interest

CS is a former member of the editorial board of BJA Education. The other authors declare that they have no conflicts of interest.
  7 in total

1.  Fresh gas flow during total intravenous anaesthesia and marginal gains in sustainable healthcare. Comment on Br J Anaesth 2020; 125: 773-8.

Authors:  Morgan Back; Adam Al-Attar; Rebecca Sutton; Clifford Shelton
Journal:  Br J Anaesth       Date:  2021-01-15       Impact factor: 9.166

2.  Air-oxygen mixtures in circle systems.

Authors:  J F Hendrickx; S De Cooman; D M Vandeput; J Van Alphen; J Coddens; T Deloof; A M De Wolf
Journal:  J Clin Anesth       Date:  2001-09       Impact factor: 9.452

3.  Environmental and economic impact of using increased fresh gas flow to reduce carbon dioxide absorbent consumption in the absence of inhalational anaesthetics.

Authors:  George Zhong; Ali Abbas; Joseph Jones; Sarah Kong; Tim McCulloch
Journal:  Br J Anaesth       Date:  2020-08-25       Impact factor: 9.166

4.  High fresh gas flow during non-inhalational anaesthesia during the COVID-19 pandemic. Comment on Br J Anaesth 2020; 125: 773-778.

Authors:  Alexander Hall; Abhijoy Chakladar
Journal:  Br J Anaesth       Date:  2020-10-02       Impact factor: 9.166

5.  Oxygen provision to fight COVID-19 in sub-Saharan Africa.

Authors:  Felix Stein; Meghan Perry; Geoffrey Banda; Mark Woolhouse; Francisca Mutapi
Journal:  BMJ Glob Health       Date:  2020-06

6.  Effects of the COVID-19 pandemic on environmental sustainability in anaesthesia. Comment on Br J Anaesth 2020; 125: 680-92.

Authors:  Stuart M White; Clifford L Shelton
Journal:  Br J Anaesth       Date:  2020-12-05       Impact factor: 9.166

7.  Effects of the COVID-19 pandemic on environmental sustainability in anaesthesia. Response to Br J Anaesth 2021;126:e118-e119.

Authors:  Forbes McGain; Jane Muret; Cathy Lawson; Jodi D Sherman
Journal:  Br J Anaesth       Date:  2020-12-03       Impact factor: 9.166

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.