Literature DB >> 33836856

Three-dimensional positional accuracy of intraoral and laboratory implant scan bodies.

Janice Zhi Hui Tan1, Ming Yi Tan2, Yoong Liang See Toh3, Kuan Yee Wong4, Keson Beng Choon Tan5.   

Abstract

STATEMENT OF PROBLEM: In the implant digital workflow, scan bodies provide the 3D position of digital implants in the virtual dental arch. However, limited evidence is available on scan body accuracy, selection, and usage.
PURPOSE: The purpose of this in vitro study was to evaluate the 3D positional accuracy of 4 intraoral and 6 laboratory scan body systems to the implants and laboratory replicas of an implant system under various torque magnitudes.
MATERIAL AND METHODS: Ten test groups comprising 4 intraoral (I): Medentika L-Series (MS), Straumann CARES Mono (SM), Core 3D (CO), Straumann RC (SS); and 6 laboratory (L): Nobel Procera Pos Locator (NP), Sirona InPost (SR), Amann Girrbach (AG), Straumann CARES Mono (SM), Core 3D (CO), Straumann RC (SS) scan bodies were derived from 7 scan body systems. Of these, 3 systems (SM, CO, SS) are used for both intraoral and laboratory applications. The scan bodies were tested on Straumann Bone Level Regular CrossFit implants or laboratory replicas. Eight test groups allowed for the variation of torque application (5, 10, and 15 Ncm), while 2 test groups (NP, SR) were hand positioned only. Prefabricated metal abutments (ME) for both implants and laboratory replicas served as controls. A coordinate measuring machine measured four 3D positional accuracy variables: vertical linear distortion (dz), 2D tolerance displacement (dr), global linear distortion (dR), and scan body height discrepancy (ΔH) (n=10). The data were analyzed with 2-way analysis of variance tests and post hoc analysis with Tukey tests (α=.05).
RESULTS: For both intraoral and laboratory test groups, 2-way ANOVA found that the system had a significant effect on all distortion variables (P<.001), while torque magnitude had a significant effect only on dz and ΔH (P<.001). Overall, mean dz ranged from 5 ±12 μm for L-AG at 15 Ncm to 23 ±14 μm for L-AG at 5 Ncm. Mean dr ranged from 5 ±4 μm for I-SM at 15 Ncm to 73 ±41 μm for L-SS at 10 Ncm, and mean dR ranged from 11 ±6 μm for I-SM at 10 Ncm to 74 ±41 μm for L-SS at 10 Ncm. Mean ΔH ranged from -5 ±10 μm for I-SM at 15 Ncm to 23 ±14 μm for L-AG at 5 Ncm. Among intraoral test groups, for dz and ΔH, all the test groups except for I-SM at 15 Ncm and I-MS at 10 and 15 Ncm were significantly more positive than the control (P<.001). For dr, I-SS at 5, 10, and 15 Ncm was significantly different from the control (P<.001). For dR, only I-SS at 5 Ncm was significantly different from the control (P<.001). Among laboratory test groups, for dz and ΔH, L-AG at 5 Ncm and L-CO at 15 Ncm were significantly more positive than the control (P<.001). For dr, L-SS at 10 and 15 Ncm were significantly different from the control (P<.001). For dR, only L-SS at 10 Ncm was significantly different from the control (P<.001). Intraoral and laboratory systems show comparable 3D positional accuracy.
CONCLUSIONS: Overall, I-SS and L-SS were the least accurate. The system tested had a significant effect on 3D positional accuracy, while torque magnitude had no consistent effect across all systems.
Copyright © 2020 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

Entities:  

Year:  2021        PMID: 33836856     DOI: 10.1016/j.prosdent.2020.09.057

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  1 in total

1.  Trueness of digital implant impressions based on implant angulation and scan body materials.

Authors:  Jae-Hyun Lee; Jae-Hwi Bae; Su Young Lee
Journal:  Sci Rep       Date:  2021-11-08       Impact factor: 4.379

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.