Literature DB >> 33812214

Combination of polycarboxybetaine coating and factor XII inhibitor reduces clot formation while preserving normal tissue coagulation during extracorporeal life support.

Noritsugu Naito1, Rei Ukita1, Jonas Wilbs2, Kan Wu3, Xiaojie Lin3, Neil M Carleton1, Kalliope Roberts1, Shaoyi Jiang3, Christian Heinis2, Keith E Cook4.   

Abstract

Blood contact with high surface area medical devices, such as dialysis and extracorporeal life support (ECLS), induces rapid surface coagulation. Systemic anticoagulation, such as heparin, is thus necessary to slow clot formation, but some patients suffer from bleeding complications. Both problems might be reduced by 1) replacing heparin anticoagulation with artificial surface inhibition of the protein adsorption that initiates coagulation and 2) selective inhibition of the intrinsic branch of the coagulation cascade. This approach was evaluated by comparing clot formation and bleeding times during short-term ECLS using zwitterionic polycarboxybetaine (PCB) surface coatings combined with either a potent, selective, bicyclic peptide inhibitor of activated Factor XII (FXII900) or standard heparin anticoagulation. Rabbits underwent venovenous ECLS with small sham oxygenators for 60 min using three means of anticoagulation (n = 4 ea): (1) PCB coating + FXII900 infusion, (2) PCB coating + heparin infusion with an activated clotting time of 220-300s, and (3) heparin infusion alone. Sham oxygenator blood clot weights in the PCB + FXII900 and PCB + heparin groups were 4% and 25% of that in the heparin group (p < 10-6 and p < 10-5), respectively. At the same time, the bleeding time remained normal in the PCB + FXII900 group (2.4 ± 0.2 min) but increased to 4.8 ± 0.5 and 5.1 ± 0.7 min in the PCB + heparin and heparin alone groups (p < 10-4 and 0.01). Sham oxygenator blood flow resistance was significantly lower in the PCB + FXII900 and PCB + heparin groups than in the heparin only group (p < 10-6 and 10-5). These results were confirmed by gross and scanning electron microscopy (SEM) images and fibrinopeptide A (FPA) concentrations. Thus, the combined use of PCB coating and FXII900 markedly reduced sham oxygenator coagulation and tissue bleeding times versus the clinical standard of heparin anticoagulation and is a promising anticoagulation method for clinical ECLS.
Copyright © 2021 The Authors. Published by Elsevier Ltd.. All rights reserved.

Entities:  

Keywords:  Anticoagulation; Artificial lung; Extracorporeal membrane oxygenator; Factor XIIa; Zwitterionic

Mesh:

Substances:

Year:  2021        PMID: 33812214     DOI: 10.1016/j.biomaterials.2021.120778

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  6 in total

Review 1.  Coagulation and Transfusion Updates From 2021.

Authors:  Michael Fabbro; Prakash A Patel; Reney A Henderson; Daniel Bolliger; Kenichi A Tanaka; Michael A Mazzeffi
Journal:  J Cardiothorac Vasc Anesth       Date:  2022-04-06       Impact factor: 2.894

Review 2.  Uninterrupted DOACs Approach for Catheter Ablation of Atrial Fibrillation: Do DOACs Levels Matter?

Authors:  Michael Hardy; Jonathan Douxfils; Anne-Sophie Dincq; Anne-Laure Sennesael; Olivier Xhaet; Francois Mullier; Sarah Lessire
Journal:  Front Cardiovasc Med       Date:  2022-03-29

3.  Plasma Polymerized Coatings on Hollow Fiber Membranes-Applications and Their Aging Characteristics in Different Media.

Authors:  Ashok K Sharma; Stephen P Conover; Kamalesh K Sirkar
Journal:  Membranes (Basel)       Date:  2022-06-26

4.  Microgel reinforced zwitterionic hydrogel coating for blood-contacting biomedical devices.

Authors:  Mengmeng Yao; Zhijian Wei; Junjin Li; Zhicheng Guo; Zhuojun Yan; Xia Sun; Qingyu Yu; Xiaojun Wu; Chaojie Yu; Fanglian Yao; Shiqing Feng; Hong Zhang; Junjie Li
Journal:  Nat Commun       Date:  2022-09-12       Impact factor: 17.694

5.  A fibrin enhanced thrombosis model for medical devices operating at low shear regimes or large surface areas.

Authors:  Rodrigo Méndez Rojano; Angela Lai; Mansur Zhussupbekov; Greg W Burgreen; Keith Cook; James F Antaki
Journal:  PLoS Comput Biol       Date:  2022-10-03       Impact factor: 4.779

Review 6.  Bioengineering Progress in Lung Assist Devices.

Authors:  Ahad Syed; Sarah Kerdi; Adnan Qamar
Journal:  Bioengineering (Basel)       Date:  2021-06-28
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.