Tereza Kůdelová1, Erik Bartuli1, Alan Strunga1, Jiří Hvožďa1, Miroslav Dohnal2.
Abstract
Access to pure water is a very topical issue today. Desalination represents a promising way of obtaining drinking water in areas of shortage. Currently, efforts are being made to replace the metal components of existing desalination units due to the high corrosivity of sea water. Another requirement is easy transportation and assembly. The presented solution combines two types of polymeric hollow fibers that are used to create the distillation unit. Porous polypropylene hollow fiber membranes have been used as an active surface for mass transfer in the distillation unit, while non-porous thermal polypropylene hollow fibers have been employed in the condenser. The large active area to volume ratio of the hollow fiber module improves the efficiency of both units. Hot water is pumped inside the membranes in the distillation unit. Evaporation is first observed at a temperature gradient of 10 °C. The water vapor flows through the tunnel to the condenser where cold water runs inside the fibers. The temperature gradient causes condensation of the vapor, and the condensate is collected. The article presents data for hot water at temperatures of 55, 60, and 65 °C. Optimization of the membrane module is evaluated and presented.Entities:
Keywords: heat transfer; hollow fiber membranes; polypropylene; sweep gas membrane distillation
Year: 2021 PMID: 33810297 PMCID: PMC8037513 DOI: 10.3390/polym13071031
Source DB: PubMed Journal: Polymers (Basel) ISSN: 2073-4360 Impact factor: 4.329
Figure 1An electron microscope image of the porous polypropylene membrane that was used for distillation; the photograph was provided by ZENA s.r.o. [27].
Figure 2A condenser made of non-porous polypropylene hollow fibers.
Properties of membrane modules.
| Membrane Module | No. of Fibers | OD (mm) | ID (mm) | Fiber Length (mm) | Mass Transfer Area (m2) | Note |
|---|---|---|---|---|---|---|
| MM001 | 4000 | 0.33 | 0.24 | 300 | 1.24 | four-bundle membrane module |
| MM002 | 200 | 0.6 | 0.48 | 140 | 0.06 | single-bundle membrane module |
| MM003 | 300 | 0.6 | 0.48 | 140 | 0.08 | single-bundle membrane module |
| MM004 | 500 | 0.6 | 0.48 | 140 | 0.14 | single-bundle membrane module |
| MM006 | 600 | 0.6 | 0.48 | 140 | 0.16 | double-bundle membrane module |
| MM007 | 1000 | 0.6 | 0.48 | 140 | 0.29 | double-bundle membrane module |
Figure 3Single-bundle membrane module MM003 (left) and double-bundle membrane module MM006 (right).
Figure 4Scheme of the test rig for MM001 (left) and for other membrane modules (right), top view.
Figure 5MM001 (right) with the condenser (left) inside the tunnel, the air flows from the right to the left.
Figure 6Testing section with MM007, condenser, MM004 and condenser (from right to left).
Measured temperatures and humidity for MM001.
| Qm (L/h) | Tmi (°C) | Tmo (°C) | Tci (°C) | Tco (°C) | H1 (%) | T1 (°C) | H2 (%) | T2 (°C) | H3 (%) | T3 (°C) | H4 (%) | T4 (°C) | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| EX01 | 60 | 55.1 | 52.2 | 10.6 | 11.1 | 83.3 | 19.9 | 93.2 | 24.9 | 88.0 | 17.3 | 88.2 | 19.0 |
| EX02 | 100 | 55.1 | 53.4 | 10.6 | 11.1 | 82.7 | 19.8 | 93.4 | 24.6 | 89.7 | 17.4 | 85.9 | 19.0 |
| EX03 | 60 | 60.1 | 57.2 | 10.5 | 11.0 | 93.2 | 19.5 | 92.7 | 25.1 | 89.6 | 17.7 | 85.0 | 18.7 |
| EX04 | 100 | 60.2 | 58.5 | 10.2 | 10.7 | 81.0 | 19.6 | 93.3 | 24.8 | 85.8 | 17.3 | 84.1 | 18.8 |
| EX05 | 60 | 65.0 | 61.9 | 10.7 | 11.2 | 82.6 | 20.1 | 93.3 | 26.2 | 86.6 | 18.2 | 89.0 | 19.3 |
| EX06 | 100 | 65.1 | 63.0 | 10.6 | 11.2 | 83.8 | 20.1 | 93.7 | 26.1 | 86.4 | 18.2 | 86.7 | 19.3 |
Thermal performance, measurement error, condensate amount, permeate flux, and membrane module pressure drop for MM001.
| Qm (L/h) | Thermal | Error (%) | Amount of Condensate (mL/h) | Permeate Flux (kg/m2h) | Pressure Drop of Membrane Module (kPa) | |
|---|---|---|---|---|---|---|
| EX01 | 60 | 0.73 | 3 | 780 | 0.62 | 26 |
| EX02 | 100 | 0.72 | 5 | 790 | 0.64 | 44 |
| EX03 | 60 | 0.73 | 3 | 800 | 0.66 | 23 |
| EX04 | 100 | 0.72 | 5 | 880 | 0.71 | 40 |
| EX05 | 60 | 0.78 | 3 | 950 | 0.77 | 21 |
| EX06 | 100 | 0.88 | 3 | 976 | 0.79 | 35 |
Measured temperatures and humidity for combination of MM004 and MM007 and two condensers.
| Qm (L/h) | Tmi (°C) | Tmo (°C) | Tci (°C) | Tco (°C) | H1 (%) | T1 (°C) | H3 (%) | T3 (°C) | H4 (%) | T4 (°C) | |
|---|---|---|---|---|---|---|---|---|---|---|---|
| EX07 | 100 | 55.4 | 53.3 | 11.5 | 11.8 | 68.6 | 21.6 | 86.2 | 17.1 | 75.9 | 19.4 |
| EX08 | 150 | 55.2 | 53.6 | 11.4 | 11.8 | 68.6 | 21.4 | 86.2 | 17.6 | 76.0 | 19.8 |
| EX09 | 120 | 59.0 | 57.3 | 11.3 | 11.7 | 68.5 | 21.13 | 87.0 | 17.2 | 75.9 | 19.4 |
| EX10 | 150 | 61.4 | 59.9 | 11.4 | 11.8 | 70.6 | 21.35 | 85.9 | 17.5 | 76.9 | 19.5 |
| EX11 | 360 | 65.5 | 64.9 | 11.6 | 12.0 | 70.4 | 21.4 | 87.6 | 17.7 | 77.7 | 19.7 |
Thermal performance, measurement error, condensate amount, permeate flux, and membrane module pressure drop for combination of MM004 and MM007 and two condensers.
| Qm (L/h) | Thermal | Error (%) | Amount of Condensate (mL/h) | Permeate Flux (kg/m2h) | Pressure Drop of Membrane Modules (kPa) | |
|---|---|---|---|---|---|---|
| EX07 | 100 | 0.85 | 3 | 185 | 0.46 | 3 |
| EX08 | 150 | 1.0 | 4 | 240 | 0.60 | 5 |
| EX09 | 120 | 0.89 | 4 | 220 | 0.55 | 4 |
| EX10 | 150 | 0.96 | 2 | 260 | 0.65 | 5 |
| EX11 | 360 | 0.95 | 4 | 300 | 0.75 | 21 |
Measured temperatures and humidity for MM003.
| Qm (L/h) | Tmi (°C) | Tmo (°C) | Tci (°C) | Tco (°C) | H1 (%) | T1 (°C) | H3 (%) | T3 (°C) | H4 (%) | T4 (°C) | |
|---|---|---|---|---|---|---|---|---|---|---|---|
| EX12 | 180 | 54.7 | 54.1 | 12.4 | 12.8 | 81.4 | 21.5 | 90.0 | 18.9 | 79.0 | 20.3 |
| EX13 | 480 | 60.0 | 59.8 | 12.6 | 12.9 | 77.0 | 24.2 | 88.0 | 21.1 | 77.0 | 22.6 |
| EX14 | 180 | 64.6 | 63.8 | 12.8 | 13.2 | 78.4 | 24.1 | 92.6 | 21.2 | 78.5 | 22.4 |
Thermal performance, measurement error, condensate amount, permeate flux, and membrane module pressure drop for MM003.
| Qm (L/h) | Thermal | Error (%) | Amount of Condensate (mL/h) | Permeate Flux (kg/m2h) | Pressure Drop of Membrane Modules (kPa) | |
|---|---|---|---|---|---|---|
| EX12 | 180 | 0.47 | 3 | 140 | 1.75 | 69 |
| EX13 | 480 | 0.51 | 2 | 170 | 2.13 | 100 |
| EX14 | 180 | 0.6 | 1 | 190 | 2.38 | 68 |
Measured temperatures and humidity for MM006.
| Qm (L/h) | Tmi (°C) | Tmo (°C) | Tci (°C) | Tco (°C) | H1 (%) | T1 (°C) | H3 (%) | T3 (°C) | H4 (%) | T4 (°C) | |
|---|---|---|---|---|---|---|---|---|---|---|---|
| EX15 | 240 | 54.3 | 53.7 | 11.4 | 11.8 | 75.7 | 21.7 | 90.0 | 18.9 | 79.0 | 20.3 |
| EX16 | 300 | 59.1 | 58.5 | 11.1 | 11.6 | 80.8 | 19.7 | 88.0 | 21.1 | 77.0 | 22.6 |
| EX17 | 300 | 64.4 | 63.9 | 11.1 | 11.6 | 84.0 | 20.0 | 92.6 | 21.2 | 78.5 | 22.4 |
Thermal performance, measurement error, condensate amount, permeate flux, and membrane module pressure drop for MM006.
| Qm (L/h) | Thermal | Error (%) | Amount of Condensate (mL/h) | Permeate Flux (kg/m2h) | Pressure Drop of Membrane Modules (kPa) | |
|---|---|---|---|---|---|---|
| EX15 | 240 | 0.6 | 1 | 180 | 1.13 | 35 |
| EX16 | 300 | 0.76 | 1 | 190 | 1.19 | 40 |
| EX17 | 300 | 0.76 | 3 | 220 | 1.38 | 40 |
Figure 7MM002 during experiment.
Measured temperatures and humidity for MM002.
| Qm (L/h) | Tmi (°C) | Tmo (°C) | Tci (°C) | Tco (°C) | H1 (%) | T1 (°C) | H3 (%) | T3 (°C) | H4 (%) | T4 (°C) | |
|---|---|---|---|---|---|---|---|---|---|---|---|
| EX18 | 270 | 55.1 | 54.7 | 11.9 | 12.2 | 66.1 | 21.1 | 73.4 | 19.1 | 77.7 | 20.5 |
| EX19 | 270 | 60.0 | 59.7 | 12.0 | 12.3 | 80.0 | 21.5 | 87.0 | 18.9 | 77.0 | 20.3 |
| EX20 | 270 | 65.2 | 64.9 | 12.1 | 12.4 | 81.0 | 21.6 | 88.0 | 19.0 | 78.0 | 20.4 |
Thermal performance, measurement error, condensate amount, permeate flux, and membrane module pressure drop for MM002.
| Qm (L/h) | Thermal | Error (%) | Amount of Condensate (mL/h) | Permeate Flux (kg/m2h) | Pressure Drop of Membrane Modules (kPa) | |
|---|---|---|---|---|---|---|
| EX18 | 270 | 0.45 | 2 | 130 | 2.61 | 100 |
| EX19 | 270 | 0.41 | 3 | 130 | 2.61 | 100 |
| EX20 | 270 | 0.41 | 1 | 130 | 2.61 | 100 |
Figure 8The comparison of the permeate flux depending on the input temperature of the membrane module.
Figure 9The dependence of the amount of condensate on the input temperature of the membrane module.
Comparison of experiments EX14, EX17, and EX18 with other published results.
| Reference | Solution | Feed Input Temperature (°C) | Permeate Flux (kg/m2h) | Flowrate (L/h) | Flow | Amount of Condensate (mL/h) |
|---|---|---|---|---|---|---|
| EX14 | water | 65 | 2.38 | 180 | 1.24 | 190 |
| EX17 | water | 65 | 1.38 | 300 | 1.38 | 220 |
| EX18 | water | 55 | 2.61 | 270 | 0.62 | 130 |
| Matheswaran et al. [ | HNO3 (252 g/L) | 60 | 0.5 | 3 | n/a 1 | n/a 1 |
| Geng et al. [ | NaCl (30 g/L) | 70 | 2.3 | 10 | n/a 1 | n/a 1 |
| Ho et al. [ | NaCl (35 g/L) | 55 | 4.659 | 54 | n/a 1 | n/a 1 |
| Eykens et al. [ | water | 60 | 5 | n/a 1 | 0.13 | n/a 1 |
n/a 1—not available.