Kinematic Comparison between Medially Congruent and Posterior-Stabilized Third-Generation TKA Designs.

Stefano Ghirardelli1, Jessica L Asay1, Erika A Leonardi1, Tommaso Amoroso1, Thomas P Andriacchi1, Pier Francesco Indelli1.   

Abstract

Background: This study compares knee kinematics in two groups of patients who have undergone primary total knee arthroplasty (TKA) using two different modern designs: medially congruent (MC) and posterior-stabilized (PS). The aim of the study is to demonstrate only minimal differences between the groups.
Methods: Ten TKA patients (4 PS, 6 MC) with successful clinical outcomes were evaluated through 3D knee kinematics analysis performed using a multicamera optoelectronic system and a force platform. Extracted kinematic data included knee flexion angle at heel-strike (KFH), peak midstance knee flexion angle (MSKFA), maximum and minimum knee adduction angle (KAA), and knee rotational angle at heel-strike. Data were compared with a group of healthy controls.
Results: There were no differences in preferred walking speed between MC and PS groups, but we found consistent differences in knee function. At heel-strike, the knee tended to be more flexed in the PS group compared to the MC group; the MSKFA tended to be higher in the PS group compared to the MC group. There was a significant fluctuation in KAA during the swing phase in the PS group compared to the MC group, PS patients showed a higher peak knee flexion moment compared to MC patients, and the PS group had significantly less peak internal rotation moments than the MC group. Conclusions: Modern, third-generation TKA designs failed to reproduce normal knee kinematics. MC knees tended to reproduce a more natural kinematic pattern at heel-strike and during axial rotation, while PS knees showed better kinematics during mid-flexion.

Entities:  

Keywords:  MC; PS; TKA; biomechanics; gait; kinematic; knee; medial pivot; posterior-stabilized; total knee arthroplasty

Year:  2021        PMID: 33804113     DOI: 10.3390/jfmk6010027

Source DB:  PubMed          Journal:  J Funct Morphol Kinesiol        ISSN: 2411-5142


  2 in total

1.  Medial congruent polyethylene design show different tibiofemoral kinematics and enhanced congruency compared to a standard symmetrical cruciate retaining design for total knee arthroplasty-an in vivo randomized controlled study of gait using dynamic radiostereometry.

Authors:  Emil Toft Petersen; Søren Rytter; Daan Koppens; Jesper Dalsgaard; Torben Bæk Hansen; Michael Skipper Andersen; Maiken Stilling
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2022-07-09       Impact factor: 4.342

2.  Intraoperative Load Sensing in Total Knee Arthroplasty Leads to a Functional but Not Clinical Difference: A Comparative, Gait Analysis Evaluation.

Authors:  Michele Giuntoli; Michelangelo Scaglione; Enrico Bonicoli; Nicola Piolanti; Gianmarco Puccioni; Karlos Zepeda; Emanuele Giannini; Stefano Marchetti; Pier Francesco Indelli
Journal:  J Funct Morphol Kinesiol       Date:  2022-02-18