Literature DB >> 33800771

Radio-Frequency Biosensors for Real-Time and Continuous Glucose Detection.

Chorom Jang1, Hee-Jo Lee2, Jong-Gwan Yook1.   

Abstract

This review paper focuses on radio-frequency (RF) biosensors for real-time and continuous glucose sensing reported in the literature, including our recent research. Diverse versions of glucose biosensors based on RF devices and circuits are briefly introduced, and their performances are compared. In addition, the limitations of the developed RF glucose biosensors are discussed. Finally, we present perspectives on state-of-art RF biosensing chips for point-of-care diagnosis and describe their future challenges.

Entities:  

Keywords:  biosensor; diabetes; glucose; insulin; microwave; radio-frequency; real-time

Mesh:

Substances:

Year:  2021        PMID: 33800771      PMCID: PMC7961512          DOI: 10.3390/s21051843

Source DB:  PubMed          Journal:  Sensors (Basel)        ISSN: 1424-8220            Impact factor:   3.576


  51 in total

1.  Electrode systems for continuous monitoring in cardiovascular surgery.

Authors:  L C CLARK; C LYONS
Journal:  Ann N Y Acad Sci       Date:  1962-10-31       Impact factor: 5.691

2.  The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues.

Authors:  S Gabriel; R W Lau; C Gabriel
Journal:  Phys Med Biol       Date:  1996-11       Impact factor: 3.609

3.  Electrochemical biosensors.

Authors:  J E Frew; H A Hill
Journal:  Anal Chem       Date:  1987-08-01       Impact factor: 6.986

4.  Ferrocene-mediated enzyme electrode for amperometric determination of glucose.

Authors:  A E Cass; G Davis; G D Francis; H A Hill; W J Aston; I J Higgins; E V Plotkin; L D Scott; A P Turner
Journal:  Anal Chem       Date:  1984-04       Impact factor: 6.986

5.  The enzyme electrode.

Authors:  S J Updike; G P Hicks
Journal:  Nature       Date:  1967-06-03       Impact factor: 49.962

6.  Amperometric biosensor based on glucose dehydrogenase and plasma-polymerized thin films.

Authors:  Atsunori Hiratsuka; Kohta Fujisawa; Hitoshi Muguruma
Journal:  Anal Sci       Date:  2008-04       Impact factor: 2.081

Review 7.  Radio-Frequency and Microwave Techniques for Non-Invasive Measurement of Blood Glucose Levels.

Authors:  Tuba Yilmaz; Robert Foster; Yang Hao
Journal:  Diagnostics (Basel)       Date:  2019-01-08

8.  A non-enzymatic glucose sensor enabled by bioelectronic pH control.

Authors:  Xenofon Strakosas; John Selberg; Pattawong Pansodtee; Nebyu Yonas; Pattawut Manapongpun; Mircea Teodorescu; Marco Rolandi
Journal:  Sci Rep       Date:  2019-07-26       Impact factor: 4.379

9.  Real-Time Noninvasive Measurement of Glucose Concentration Using a Modified Hilbert Shaped Microwave Sensor.

Authors:  Levon Odabashyan; Arsen Babajanyan; Zhirayr Baghdasaryan; Seungwan Kim; Jongchel Kim; Barry Friedman; Jung-Ha Lee; Kiejin Lee
Journal:  Sensors (Basel)       Date:  2019-12-13       Impact factor: 3.576

10.  Non-invasive continuous-time glucose monitoring system using a chipless printable sensor based on split ring microwave resonators.

Authors:  Masoud Baghelani; Zahra Abbasi; Mojgan Daneshmand; Peter E Light
Journal:  Sci Rep       Date:  2020-07-31       Impact factor: 4.379

View more
  1 in total

1.  The Automatic Design of Multimode Resonator Topology with Evolutionary Algorithms.

Authors:  Vladimir V Stanovov; Sergey A Khodenkov; Aleksey M Popov; Lev A Kazakovtsev
Journal:  Sensors (Basel)       Date:  2022-03-02       Impact factor: 3.576

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.