Literature DB >> 33784624

On the Non-idealities of a Capacitive Link for Wireless Power Transfer to Biomedical Implants.

A N M Shahriyar Hossain, Reza Erfani, Pedram Mohseni, Hossein Miri Lavasani.   

Abstract

This paper studies the performance of a resonant capacitive wireless power transfer (C-WPT) link for biomedical implants in the presence of non-idealities. The study emphasizes on finding an accurate electrical model of a practical C-WPT link, which can be used to investigate the performance of the link under different practical/non-ideal scenarios. A sound knowledge about these non-idealities is crucial for device optimization. For the first time, a circuit model has been presented and analyzed, which is applicable to a practical C-WPT link undergoing plate mismatch, flexion, tissue contraction, and stretching. Our model considers the finite conductivity of the body tissue and fringe fields formed by capacitor plates. Analytical and HFSSTM simulation results have been presented for different non-idealities, and are in good agreement. Additionally, we show a procedure to interpolate non-ideal case results. The study shows that plate misalignment (causing reduction in parallel plate overlap area) and skin tissue contraction (while muscle grows) are the most detrimental individual factors to the link performance. We recorded ∼32% and ∼14% power transfer efficiency decrease due to these two worst-case scenarios, respectively for a C-WPT link comprising of two pairs of 400 mm2 parallel plates (12 cm edge-to-edge separation) coated with 63.5 µm thick Kapton layer and aligned around a 3 mm tissue at 20 MHz.

Year:  2021        PMID: 33784624     DOI: 10.1109/TBCAS.2021.3069842

Source DB:  PubMed          Journal:  IEEE Trans Biomed Circuits Syst        ISSN: 1932-4545            Impact factor:   3.833


  2 in total

1.  Floating EMG sensors and stimulators wirelessly powered and operated by volume conduction for networked neuroprosthetics.

Authors:  Laura Becerra-Fajardo; Marc Oliver Krob; Jesus Minguillon; Camila Rodrigues; Christine Welsch; Marc Tudela-Pi; Albert Comerma; Filipe Oliveira Barroso; Andreas Schneider; Antoni Ivorra
Journal:  J Neuroeng Rehabil       Date:  2022-06-07       Impact factor: 5.208

2.  Wireless power transfer system for deep-implanted biomedical devices.

Authors:  Amjad Iqbal; Penchala Reddy Sura; Muath Al-Hasan; Ismail Ben Mabrouk; Tayeb A Denidni
Journal:  Sci Rep       Date:  2022-08-11       Impact factor: 4.996

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.